Prospective assessment of plate-haptic rotationally asymmetric multifocal toric intraocular lens with near addition of + 1.5 diopters.
Oshika, Tetsuro; Negishi, Kazuno; Noda, Toru; Arai, Hiroyuki; Inamura, Mikio; Inoue, Yasushi; Miyoshi, Teruyuki; Fujita, Yoshifumi; Miyata, Kazunori; Hasegawa, Yumi.
Afiliación
  • Oshika T; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki, 305-8575, Japan. oshika@eye.ac.
  • Negishi K; Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan.
  • Noda T; Department of Ophthalmology, National Hospital Organization, Tokyo Medical Center, Tokyo, Japan.
  • Arai H; Queen's Eye Clinic, Yokohama, Kanagawa, Japan.
  • Inamura M; Inamura Eye Clinic, Yokohama, Kanagawa, Japan.
  • Inoue Y; Inoue Eye Clinic, Tamano, Okayma, Japan.
  • Miyoshi T; Miyoshi Eye Clinic, Fukuyama, Hiroshima, Japan.
  • Fujita Y; Fujita Eye Clinic, Tokushima, Tokushima, Japan.
  • Miyata K; Miyata Eye Hospital, Miyakonojo, Miyazaki, Japan.
  • Hasegawa Y; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki, 305-8575, Japan.
BMC Ophthalmol ; 20(1): 454, 2020 Nov 18.
Article en En | MEDLINE | ID: mdl-33208137
ABSTRACT

BACKGROUND:

To prospectively evaluate surgical results following implantation of rotationally asymmetric, plate-haptic, refractive segmented multifocal toric intraocular lenses (IOLs) with near addition of + 1.5 diopters (D) (Lentis Comfort LS-313 MF15T, Oculentis GmbH).

METHODS:

In 59 eyes of 41 patients, ocular examinations were conducted before and 1 day, 1 week, 1, 3, and 6 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were tested. A defocus curve was drawn, and the degree of disturbing photic phenomena were questioned.

RESULTS:

The IOL showed excellent rotational stability; the average absolute rotation was 1.66 ± 1.17 degrees from 1 day 1 to 6 months postoperatively, and 98.1 and 100% of eyes yielded rotation of less than 5 and 10 degrees, respectively. Postoperative distance and intermediate visual acuity were highly satisfactory; UDVA, CDVA, UIVA, and DCIVA were about 20/20, 20/16, 20/25, 20/25, respectively. Near visual acuity was suboptimal; UNVA and DCNVA were at approximately 20/60. The defocus curve analysis showed that 20/25 and 20/40 uncorrected visual acuity was attained at as close as 60 and 40 cm, respectively. Contrast sensitivity was within a normal range, and subjective photic phenomena were minimum.

CONCLUSIONS:

The refractive segmented, rotationally asymmetric multifocal toric IOLs with + 1.5 D near addition showed superb rotational stability and highly satisfactory distance and intermediate vision. Contrast sensitivity was high and incidence of photic symptoms was very low. TRIAL REGISTRATION This study was registered at JAPIC Clinical Trials Information, ID JapicCTI-183,877, https//www.clinicaltrials.jp/cti-user/trial/Search.jsp (February 5, 2018).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Facoemulsificación / Lentes Intraoculares Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Facoemulsificación / Lentes Intraoculares Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Japón