Your browser doesn't support javascript.
loading
Characterisation of new reference materials IAEA-610, IAEA-611 and IAEA-612 aimed at the VPDB δ13 C scale realisation with small uncertainty.
Assonov, Sergey; Fajgelj, Ales; Hélie, Jean-François; Allison, Colin; Gröning, Manfred.
Afiliación
  • Assonov S; International Atomic Energy Agency (IAEA), Wagramerstrasse 5, Vienna, 1400, Austria.
  • Fajgelj A; International Atomic Energy Agency (IAEA), Wagramerstrasse 5, Vienna, 1400, Austria.
  • Hélie JF; Université du Québec à Montréal, Montréal, QC, H2X 3Y7, Canada.
  • Allison C; CSIRO, GPO Box 1700, Canberra, ACT 2601, Australia.
  • Gröning M; International Atomic Energy Agency (IAEA), Wagramerstrasse 5, Vienna, 1400, Austria.
Rapid Commun Mass Spectrom ; 35(7): e9014, 2021 Apr 15.
Article en En | MEDLINE | ID: mdl-33270300
ABSTRACT
RATIONALE LSVEC, the second anchor Reference Material (RM) for the VPDB δ13 C scale realisation, was introduced in 2006. In 2015, its δ13 C value was found to be drifting and, in 2017, its use as an RM for δ13 C was officially discontinued by IUPAC. New RMs of low uncertainty are needed. This paper describes the preparation and characterisation of IAEA-610, IAEA-611 and IAEA-612 (calcium carbonate, of chemical origin) which shall serve as a set of RMs aimed at anchoring the VPDB scale at negative δ13 C values.

METHODS:

The preparation and characterisation of IAEA-610, IAEA-611 and IAEA-612 were performed by addressing the contemporary technical requirements for RM production and characterisation (ISO Guide 352017). The three RMs were produced in large quantities, and the first batch was sealed into ampoules (0.5 g) to ensure the integrity of the RM during storage; additional batches were sealed for long-term storage. The most accurate method of CO2 preparation and stable isotope measurements was used, namely carbonate-H3 PO4 reaction under well-controlled conditions combined with well-tested stable isotope ratio mass spectrometry.

RESULTS:

The assigned values of δ13 C and associated uncertainties are based on a large number of analyses (~10 mg aliquots) performed at IAEA and address all the known uncertainty components. For aliquots down to ~100 µg, the δ13 C uncertainty is increased. The uncertainty components considered are as follows (i) material homogeneity, (ii) value assignment against IAEA-603, (iii) potential storage effects, (iv) effect of the 17 O correction, and (v) mass spectrometer linearity and cross-contamination memory in the ion source.

CONCLUSIONS:

The new RMs IAEA-610, IAEA-611 and IAEA-612 have been characterised on the VPDB δ13 C scale in a mutually consistent way. The use of three RMs will allow a consistent realisation of the VPDB δ13 C scale with small uncertainty to be established, and to reach metrological compatibility of measurement results over several decades.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rapid Commun Mass Spectrom Año: 2021 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rapid Commun Mass Spectrom Año: 2021 Tipo del documento: Article País de afiliación: Austria