Your browser doesn't support javascript.
loading
Sufficient sampling for kriging prediction of cortical potential in rat, monkey, and human µECoG.
Trumpis, Michael; Chiang, Chia-Han; Orsborn, Amy L; Bent, Brinnae; Li, Jinghua; Rogers, John A; Pesaran, Bijan; Cogan, Gregory; Viventi, Jonathan.
Afiliación
  • Trumpis M; Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America.
  • Chiang CH; Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America.
  • Orsborn AL; Center for Neural Science, New York University, New York, NY 10003, United States of America.
  • Bent B; Department of Electrical & Computer Engineering, University of Washington, Seattle, WA 98195, United States of America.
  • Li J; Department of Bioengineering, University of Washington, Seattle, Washington 98105, United States of America.
  • Rogers JA; Washington National Primate Research Center, Seattle, Washington 98195, United States of America.
  • Pesaran B; Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America.
  • Cogan G; Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, United States of America.
  • Viventi J; Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, United States of America.
J Neural Eng ; 18(3)2021 03 08.
Article en En | MEDLINE | ID: mdl-33326943
ABSTRACT
Objective. Large channel count surface-based electrophysiology arrays (e.g. µECoG) are high-throughput neural interfaces with good chronic stability. Electrode spacing remains ad hoc due to redundancy and nonstationarity of field dynamics. Here, we establish a criterion for electrode spacing based on the expected accuracy of predicting unsampled field potential from sampled sites.Approach. We applied spatial covariance modeling and field prediction techniques based on geospatial kriging to quantify sufficient sampling for thousands of 500 ms µECoG snapshots in human, monkey, and rat. We calculated a probably approximately correct (PAC) spacing based on kriging that would be required to predict µECoG fields at≤10% error for most cases (95% of observations).Main results. Kriging theory accurately explained the competing effects of electrode density and noise on predicting field potential. Across five frequency bands from 4-7 to 75-300 Hz, PAC spacing was sub-millimeter for auditory cortex in anesthetized and awake rats, and posterior superior temporal gyrus in anesthetized human. At 75-300 Hz, sub-millimeter PAC spacing was required in all species and cortical areas.Significance. PAC spacing accounted for the effect of signal-to-noise on prediction quality and was sensitive to the full distribution of non-stationary covariance states. Our results show that µECoG arrays should sample at sub-millimeter resolution for applications in diverse cortical areas and for noise resilience.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Corteza Auditiva / Electrocorticografía Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Animals / Humans Idioma: En Revista: J Neural Eng Asunto de la revista: NEUROLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Corteza Auditiva / Electrocorticografía Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Animals / Humans Idioma: En Revista: J Neural Eng Asunto de la revista: NEUROLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos