Impact of environmental factors on the sampling rate of ß-blockers and sulfonamides from water by a carbon nanotube-passive sampler.
Godlewska, Klaudia; Jakubus, Aleksandra; Stepnowski, Piotr; Paszkiewicz, Monika.
Afiliación
  • Godlewska K; Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland. Electronic address: klaudia.godlewska@phdstud.ug.edu.pl.
  • Jakubus A; Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland.
  • Stepnowski P; Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland.
  • Paszkiewicz M; Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland.
J Environ Sci (China) ; 101: 413-427, 2021 Mar.
Article en En | MEDLINE | ID: mdl-33334535
ABSTRACT
Passive techniques are a constantly evolving approach to the long-term monitoring of micropollutants, including pharmaceuticals, in the aquatic environment. This paper presents, for the first time, the calibration results of a new CNTs-PSDs (carbon nanotubes used as a sorbent in passive sampling devices) with an examination of the effect of donor phase salinity, water pH and the concentration of dissolved humic acids (DHAs), using both ultrapure and environmental waters. Sampling rates (Rs) were determined for the developed kinetic samplers. It has been observed that the impact of the examined environmental factors on the Rs values strictly depends on the type of the analytes. In the case of ß-blockers, the only environmental parameter affecting their uptake rate was the salinity of water. A certain relationship was noted, namely the higher the salt concentration in water, the lower the Rs values of ß-blockers. In the case of sulfonamides, water salinity, water pH 7-9 and DHAs concentration decreased the uptake rate of these compounds by CNTs-PSDs. The determined Rs values differed in particular when the values obtained from the experiments carried out using ultrapure water and environmental waters were compared. The general conclusion is that the calibration of novel CNTs-PSDs should be carried out under physicochemical conditions of the aquatic phase that are similar to the environmental matrix.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Nanotubos de Carbono Idioma: En Revista: J Environ Sci (China) Asunto de la revista: SAUDE AMBIENTAL Año: 2021 Tipo del documento: Article Pais de publicación: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Nanotubos de Carbono Idioma: En Revista: J Environ Sci (China) Asunto de la revista: SAUDE AMBIENTAL Año: 2021 Tipo del documento: Article Pais de publicación: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS