Your browser doesn't support javascript.
loading
Droplet digital PCR and mile-post analysis for the detection of F8 int1h inversions.
Manderstedt, Eric; Lind-Halldén, Christina; Ljung, Rolf; Astermark, Jan; Halldén, Christer.
Afiliación
  • Manderstedt E; Department of Environmental Science and Bioscience, Kristianstad University, Kristianstad, Sweden.
  • Lind-Halldén C; Department of Environmental Science and Bioscience, Kristianstad University, Kristianstad, Sweden.
  • Ljung R; Department of Clinical Sciences - Pediatrics and Center for Thrombosis and Hemostasis, Skåne University Hospital, Malmö, Sweden.
  • Astermark J; Department of Translational Medicine and Department of Hematology Oncology and Radiation Physics, Center for Thrombosis and Hemostasis, Skåne University Hospital, Malmö, Sweden.
  • Halldén C; Department of Environmental Science and Bioscience, Kristianstad University, Kristianstad, Sweden.
J Thromb Haemost ; 19(3): 732-737, 2021 03.
Article en En | MEDLINE | ID: mdl-33345381
BACKGROUND: F8 int1h inversions (Inv1) are detected in 1%-2% of severe hemophilia A (HA) patients. Long-range polymerase chain reaction (PCR) and inverse-shifting PCR have been used to diagnose these inversions. OBJECTIVES: To design and validate a sensitive and robust assay for detection of F8 Inv1 inversions. METHODS: Archival DNA samples were investigated using mile-post assays and droplet digital PCR. RESULTS: Milepost assays for Inv1 showing high specificities and sensitivities were designed and optimized. Analysis of four patients, two carrier mothers, and 40 healthy controls showed concordance with known mutation status with one exception. One patient had a duplication involving exons 2-22 of the F8 gene instead of an Inv1 mutation. DNA mixtures with different proportions of wild-type and Inv1 DNA correlated well with the observed relative linkage for both wild type and Inv1 assays and estimated the limit of detection of these assays to 2% of the rare chromosome. CONCLUSIONS: The milepost strategy has several inherent control systems. The absolute counting of target molecules by both assays enables determination of template quantity, detection of copy number variants, and rare variants occurring in primer and probe annealing sites and estimation of DNA integrity through the observed linkage. The presented Inv1 milepost analysis offers sensitive and robust detection and quantification of the F8 int1h inversions and other rearrangements involving intron 1 in patients and their mothers.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Factor VIII / Hemofilia A Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Thromb Haemost Asunto de la revista: HEMATOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Suecia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Factor VIII / Hemofilia A Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Thromb Haemost Asunto de la revista: HEMATOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Suecia Pais de publicación: Reino Unido