Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles.
Walter, Thomas H; Alden, Bonnie A; Field, Jessica A; Lawrence, Nicole L; Osterman, Donna L; Patel, Amit V; DeLoffi, Maureen A.
Afiliación
  • Walter TH; Waters Corporation, Milford, Massachusetts, USA.
  • Alden BA; Waters Corporation, Milford, Massachusetts, USA.
  • Field JA; Waters Corporation, Milford, Massachusetts, USA.
  • Lawrence NL; Waters Corporation, Milford, Massachusetts, USA.
  • Osterman DL; Waters Corporation, Milford, Massachusetts, USA.
  • Patel AV; Waters Corporation, Milford, Massachusetts, USA.
  • DeLoffi MA; Waters Corporation, Milford, Massachusetts, USA.
J Sep Sci ; 44(5): 1005-1014, 2021 Mar.
Article en En | MEDLINE | ID: mdl-33354922
ABSTRACT
We have characterized Atlantis ethylene-bridged hybrid C18 anion-exchange, a mixed-mode reversed-phase/weak anion-exchange stationary phase designed to give greater retention for anions (e.g., ionized acids) compared to conventional reversed-phase materials. The retention and selectivity of this stationary phase were compared to that of three benchmark materials, using a mixture of six polar compounds that includes an acid, two bases, and three neutrals. The compatibility of the ethylene-bridged hybrid C18 anion-exchange material with 100% aqueous mobile phases was also evaluated. We investigated the batch-to-batch reproducibility of the ethylene-bridged hybrid C18 anion-exchange stationary phase for 27 batches across three different particle sizes (1.7, 2.5, and 5 µm) and found it to be comparable to that of one of the most reproducible C18 stationary phases. We also characterized the acid and base stability of the ethylene-bridged hybrid C18 anion-exchange stationary phase and the results show it to be usable over a wide pH range, from 2 to 10. The extended upper pH limit relative to silica-based reversed-phase/weak anion-exchange materials is enabled by the use of ethylene-bridged hybrid organic/inorganic particles. The improved base stability allows Atlantis ethylene-bridged hybrid C18 anion-exchange to be used with a wider range of mobile phase pH values, opening up a greater range of selectivity options.