Your browser doesn't support javascript.
loading
Dynamic oxygen-17 MRI with adaptive temporal resolution using golden-means-based 3D radial sampling.
Gu, Yuning; Gao, Huiyun; Kim, Kihwan; Liu, Yuchi; Ramos-Estebanez, Ciro; Luo, Yu; Wang, Yunmei; Yu, Xin.
Afiliación
  • Gu Y; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
  • Gao H; Department of Medicine, Case Western Reserve University, Cleveland, Ohio, USA.
  • Kim K; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
  • Liu Y; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
  • Ramos-Estebanez C; Department of Neurology & Rehabilitation and Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Luo Y; Department of Molecular Genetics, University of Cincinnati, Cincinnati, Ohio, USA.
  • Wang Y; Department of Medicine, Case Western Reserve University, Cleveland, Ohio, USA.
  • Yu X; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
Magn Reson Med ; 85(6): 3112-3124, 2021 06.
Article en En | MEDLINE | ID: mdl-33368649
ABSTRACT

PURPOSE:

The aim of this study was to develop a high-resolution 3D oxygen-17 (17 O) MRI method to delineate the kinetics of 17 O-enriched water (H217 O) across the entire mouse brain after a bolus injection via the tail vein.

METHODS:

The dynamic 17 O signal was acquired with a golden-means-based 3D radial sampling scheme. To achieve adequate temporal resolution with preserved spatial resolution, a k-space-weighted view sharing strategy was used in image reconstruction with an adaptive window size tailored to the kinetics of the 17 O signal. Simulation studies were performed to determine the adequate image reconstruction parameters. The established method was applied to delineating the kinetics of intravenously injected H217 O in vivo in the post-stroke mouse brain.

RESULTS:

The proposed dynamic 17 O-MRI method achieved an isotropic resolution of 1.21 mm (0.77 mm nominal) in mouse brain at 9.4T, with the temporal resolution increased gradually from 3 s at the initial phase of rapid signal increase to 15 s at the steady-state. The high spatial resolution enabled the delineation of the heterogeneous H217 O uptake and washout kinetics in stroke-affected mouse brain.

CONCLUSION:

The current study demonstrated a 3D 17 O-MRI method for dynamic monitoring of 17 O signal changes with high spatial and temporal resolution. The method can be utilized to quantify physiological parameters such as cerebral blood flow and blood-brain barrier permeability by tracking injected H217 O. It can also be used to measure oxygen consumption rate in 17 O-oxygen inhalation studies.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Imagenología Tridimensional Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Imagenología Tridimensional Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos