A comparison of optic disc area measured by confocal scanning laser tomography versus Bruch's membrane opening area measured using optical coherence tomography.
Cazana, Ioana Maria; Böhringer, Daniel; Reinhard, Thomas; Evers, Charlotte; Engesser, Diana; Anton, Alexandra; Lübke, Jan.
Afiliación
  • Cazana IM; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany. ioana.maria.cazana@uniklinik-freiburg.de.
  • Böhringer D; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Reinhard T; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Evers C; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Engesser D; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Anton A; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Lübke J; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
BMC Ophthalmol ; 21(1): 31, 2021 Jan 12.
Article en En | MEDLINE | ID: mdl-33430821
ABSTRACT

BACKGROUND:

Precise optic disc size measurements based on anatomically exact disc margins are fundamental for a correct assessment of glaucoma suspects. Computerized imaging techniques, such as confocal-scanning-laser-tomography (CSLT), which applies operator defined boundaries and optical-coherence-tomography (OCT), which incorporates an alternative detectable landmark (Bruch's-membrane-opening (BMO)), have simplified the planimetry of the optic disc and BMO-area, respectively. This study's objectives are to compare both modalities for area and to define a threshold for macro-BMO using BMO-OCT.

METHODS:

Retrospectively, patients that simultaneously received CSLT and BMO-OCT scans were included. Their images were correlated and agreement was determined using Bland-Altman-analysis. The diagnostic power of a macro-BMO threshold using OCT was derived after creating a receiver-operating-characteristics-curve using the well-established analogous CSLT threshold (2.43 mm2).

RESULTS:

Our study included 373 eyes with a median optic disc area by CSLT/ BMO-area by OCT of 2.56 mm2 and 2.19 mm2 respectively. The Bland-Altman-analysis revealed a systematic deviation with a diverging tendency with increasing area, which enabled the creation of the following mathematical relation disc-area (CSLT)*0.73 + 0.3 = BMO-area (OCT). BMO-area of 2.19 mm2 showed the best diagnostic power for identifying macro-BMOs using OCT (sensitivity 75%, specificity 86%).

CONCLUSIONS:

Area measurements (CSLT optic disc area vs. BMO-area by OCT) showed a systematic deviation with a divergent tendency with increasing size. Our mathematical equation offers an estimated comparison of these anatomically diverse entities. Considering BMO-OCT´ anatomical accuracy, the 2.19 mm2 threshold may improve discernment between glaucoma suspects and norm variants.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Tomografía de Coherencia Óptica Tipo de estudio: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Tomografía de Coherencia Óptica Tipo de estudio: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania