A comparison of optic disc area measured by confocal scanning laser tomography versus Bruch's membrane opening area measured using optical coherence tomography.
BMC Ophthalmol
; 21(1): 31, 2021 Jan 12.
Article
en En
| MEDLINE
| ID: mdl-33430821
ABSTRACT
BACKGROUND:
Precise optic disc size measurements based on anatomically exact disc margins are fundamental for a correct assessment of glaucoma suspects. Computerized imaging techniques, such as confocal-scanning-laser-tomography (CSLT), which applies operator defined boundaries and optical-coherence-tomography (OCT), which incorporates an alternative detectable landmark (Bruch's-membrane-opening (BMO)), have simplified the planimetry of the optic disc and BMO-area, respectively. This study's objectives are to compare both modalities for area and to define a threshold for macro-BMO using BMO-OCT.METHODS:
Retrospectively, patients that simultaneously received CSLT and BMO-OCT scans were included. Their images were correlated and agreement was determined using Bland-Altman-analysis. The diagnostic power of a macro-BMO threshold using OCT was derived after creating a receiver-operating-characteristics-curve using the well-established analogous CSLT threshold (2.43 mm2).RESULTS:
Our study included 373 eyes with a median optic disc area by CSLT/ BMO-area by OCT of 2.56 mm2 and 2.19 mm2 respectively. The Bland-Altman-analysis revealed a systematic deviation with a diverging tendency with increasing area, which enabled the creation of the following mathematical relation disc-area (CSLT)*0.73 + 0.3 = BMO-area (OCT). BMO-area of 2.19 mm2 showed the best diagnostic power for identifying macro-BMOs using OCT (sensitivity 75%, specificity 86%).CONCLUSIONS:
Area measurements (CSLT optic disc area vs. BMO-area by OCT) showed a systematic deviation with a divergent tendency with increasing size. Our mathematical equation offers an estimated comparison of these anatomically diverse entities. Considering BMO-OCT´ anatomical accuracy, the 2.19 mm2 threshold may improve discernment between glaucoma suspects and norm variants.Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Disco Óptico
/
Tomografía de Coherencia Óptica
Tipo de estudio:
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Humans
Idioma:
En
Revista:
BMC Ophthalmol
Asunto de la revista:
OFTALMOLOGIA
Año:
2021
Tipo del documento:
Article
País de afiliación:
Alemania