Your browser doesn't support javascript.
loading
Simultaneous determination of 79 pesticides in pigeonpea grains using GC-MS/MS and LC-MS/MS.
Harischandra, Naik R; Pallavi, M S; Bheemanna, M; PavanKumar, K; Chandra Sekhara Reddy, V; Udaykumar, Nidoni R; Paramasivam, M; Yadav, Satish.
Afiliación
  • Harischandra NR; Pesticide Residue and Food Quality Analysis Laboratory, University of Agricultural Sciences, Raichur 584 104, India. Electronic address: hrnaik@uasraichur.edu.in.
  • Pallavi MS; Pesticide Residue and Food Quality Analysis Laboratory, University of Agricultural Sciences, Raichur 584 104, India.
  • Bheemanna M; Pesticide Residue and Food Quality Analysis Laboratory, University of Agricultural Sciences, Raichur 584 104, India.
  • PavanKumar K; Pesticide Residue and Food Quality Analysis Laboratory, University of Agricultural Sciences, Raichur 584 104, India.
  • Chandra Sekhara Reddy V; Pesticide Residue and Food Quality Analysis Laboratory, University of Agricultural Sciences, Raichur 584 104, India.
  • Udaykumar NR; Pesticide Residue and Food Quality Analysis Laboratory, University of Agricultural Sciences, Raichur 584 104, India.
  • Paramasivam M; Pesticide Toxicology Laboratory, Tamil Nadu Agricultural University, Coimbatore 641003, India.
  • Yadav S; National Institute of Plant Health Management, Hyderabad, India; Arbro Pharmaceuticals Pvt., Ltd., (Analytical Division), New Delhi, India.
Food Chem ; 347: 128986, 2021 Jun 15.
Article en En | MEDLINE | ID: mdl-33515969
ABSTRACT
Pigeonpea grains are important sources of vegetarian proteins. It is the paramount importance to check the pesticide residues due to their frequent use during production. The LC-MS/MS and GC-MS/MS analytical method was developed and validated for the simultaneous determination of 79 pesticide residues in pigeonpea. The LOD and LOQ of the analytical method were in the range of 0.53 to 3.97 and 1.60 to 10.05 µg kg-1, respectively, with a correlation coefficient of more than 0.997. Average recoveries were in the range of 80 to 118.8%, with the RSD of less than 15%. Measurement uncertainty (Ux) for pesticides was in the range of 3.42 to 12.76 µg kg-1 evaluated at 50 µg kg-1. The method was applied to analyze the sample collected from the farmer's field. This method could be useful for routine analysis of selected pesticide residue for monitoring purposes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Residuos de Plaguicidas / Cajanus / Espectrometría de Masas en Tándem / Cromatografía de Gases y Espectrometría de Masas Idioma: En Revista: Food Chem Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Residuos de Plaguicidas / Cajanus / Espectrometría de Masas en Tándem / Cromatografía de Gases y Espectrometría de Masas Idioma: En Revista: Food Chem Año: 2021 Tipo del documento: Article