Your browser doesn't support javascript.
loading
Calculating the Effect of Ribs on the Focus Quality of a Therapeutic Spherical Random Phased Array.
Zubair, Muhammad; Dickinson, Robert.
Afiliación
  • Zubair M; Department of Radiation Oncology, University of California, San Francisco, CA 90007, USA.
  • Dickinson R; Department of Bioengineering, Imperial College London, London SW7 2AZ, UK.
Sensors (Basel) ; 21(4)2021 Feb 09.
Article en En | MEDLINE | ID: mdl-33572208
ABSTRACT
The overlaying rib cage is a major hindrance in treating liver tumors with high intensity focused ultrasound (HIFU). The problems caused are overheating of the ribs due to its high ultrasonic absorption capability and degradation of the ultrasound intensity distribution in the target plane. In this work, a correction method based on binarized apodization and geometric ray tracing approach was employed to avoid heating the ribs. A detailed calculation of the intensity distribution in the focus plane was undertaken to quantify and avoid the effect on HIFU beam generated by a 1-MHz 256-element random phased array after the ultrasonic beam passes through the rib cage. Focusing through the ribs was simulated for 18 different idealized ribs-array configurations and 10 anatomically correct ribs-array configurations, to show the effect of width of the ribs, intercostal spacing and the relative position of ribs and array on the quality of focus, and to identify the positions that are more effective for HIFU applications in the presence of ribs. Acoustic simulations showed that for a single focus without beam steering and for the same total acoustic power, the peak intensity at the target varies from a minimum of 211 W/cm2 to a maximum of 293 W/cm2 for a nominal acoustic input power of 15 W, whereas the side lobe level varies from 0.07 Ipeak to 0.28 Ipeak and the separation between the main lobe and side lobes varies from 2.5 mm to 6.3 mm, depending on the relative positioning of the array and ribs and the beam alignment. An increase in the side lobe level was observed by increasing the distance between the array and the ribs. The parameters of focus splitting and the deterioration of focus quality caused by the ultrasonic propagation through the ribs were quantified in various possible different clinical scenarios. In addition to idealized rib topology, anatomical realistic ribs were used to determine the focus quality of the HIFU beam when the beam is steered both in axial and transverse directions and when the transducer is positioned at different depths from the rib cage.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Costillas / Ultrasonido Enfocado de Alta Intensidad de Ablación Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Costillas / Ultrasonido Enfocado de Alta Intensidad de Ablación Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos
...