Outcome of PCI with Xience versus other commonly used modern drug eluting stents: A SCAAR report.
Grimfjärd, Per; Bergman, Elin; Buccheri, Sergio; Erlinge, David; Lagerqvist, Bo; Svennblad, Bodil; Völz, Sebastian; Angerås, Oskar; James, Stefan.
Afiliación
  • Grimfjärd P; Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden.
  • Bergman E; Department of Cardiology, Västerås Hospital, Västerås, Sweden.
  • Buccheri S; Department of Cardiology, Västerås Hospital, Västerås, Sweden.
  • Erlinge D; Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden.
  • Lagerqvist B; Uppsala Clinical Research Center, Uppsala, Sweden.
  • Svennblad B; Department of Cardiology, Clinical Sciences, Lund University, Lund, Sweden.
  • Völz S; Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden.
  • Angerås O; Uppsala Clinical Research Center, Uppsala, Sweden.
  • James S; Uppsala Clinical Research Center, Uppsala, Sweden.
Catheter Cardiovasc Interv ; 98(2): E197-E204, 2021 08 01.
Article en En | MEDLINE | ID: mdl-33719169
ABSTRACT

OBJECTIVES:

To analyze the clinical outcome of percutaneous coronary intervention (PCI) using the Xience drug eluting stent (DES) versus other modern DES.

METHODS:

This retrospective study based on the Swedish Coronary Angiography and Angioplasty Registry (SCAAR) analyzed the outcome of PCI using Xience versus other commonly used modern DES, 2007 to 2017. The primary outcome measure was a combination of all-cause death, myocardial infarction (MI) and revascularisation with PCI. Angiographical outcome measures were in-stent restenosis (ISR) and stent thrombosis (ST).

RESULTS:

Rates of the primary outcome measure for Xience and other DES were 31.9% and 28.2% respectively, adjusted hazard ratio (HR) 0.99 (95% CI 0.95-1.03). Crude rates of ISR were 2.9% versus 2.1% over 4.3 and 2.9 years respectively, adjusted HR 0.93 (95% CI 0.81-1.06). Crude rates of ST were 0.9% versus 0.7%, adjusted HR 1.07 (95% CI 0.82-1.39). Results were consistent in all sensitivity analyses.

CONCLUSIONS:

This nationally complete, real-world study confirms that Xience is a safe and effective DES with low-event rates of ISR and ST. Compared with a control group containing a large proportion of thinner strut stents and absorbable polymers, Xience exhibits similar results in all important clinical endpoints.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Angioplastia Coronaria con Balón / Reestenosis Coronaria / Stents Liberadores de Fármacos / Intervención Coronaria Percutánea Tipo de estudio: Etiology_studies / Observational_studies Límite: Humans País/Región como asunto: Europa Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Angioplastia Coronaria con Balón / Reestenosis Coronaria / Stents Liberadores de Fármacos / Intervención Coronaria Percutánea Tipo de estudio: Etiology_studies / Observational_studies Límite: Humans País/Región como asunto: Europa Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Suecia