Dosimetric Comparisons of Simulation Techniques for Left-Sided Breast Cancer in the COVID-19 Era: Techniques to Reduce Viral Transmission and Respect the Therapeutic Ratio.
Cureus
; 13(2): e13354, 2021 Feb 15.
Article
en En
| MEDLINE
| ID: mdl-33747655
Background The COVID-19 pandemic challenges our ability to safely treat breast cancer patients and requires revisiting current techniques to evaluate optimal strategies. Potential long-term sequelae of breast radiation have been addressed by deep inspiration breath-hold (DIBH), prone positioning, and four-dimensional computed tomography (4DCT) average intensity projection (AveIP)-based planning techniques. Dosimetric comparisons to determine the optimal technique to minimize the normal tissue dose for left-sided breast cancers have not been performed. Methods Ten patients with left-sided, early-stage breast cancer undergoing whole breast radiation were simulated in the prone position, supine with DIBH, and with a free-breathing 4DCT scan. The target and organs at risk (OAR) contours were delineated in all scans. Target volume coverage and OAR doses were assessed. One-way analysis of variance (ANOVA) and Kruskal-Wallis one-way ANOVA were used to detect differences in dosimetric parameters among the different treatment plans. Significance was set as p < 0.05. Results We demonstrate differences in heart and lung dose by the simulation technique. The mean heart doses in the prone, DIBH, and AveIP plans were 129 cGy, 154 cGy, and 262 cGy, respectively (p=0.02). The lung V20 in the prone, DIBH, and AveIP groups was 0.5%, 10.3% and 9.5%, respectively (p <0.001). Regardless of technique, lumpectomy planning target volume (PTV) coverage did not differ between the three plans with 95% of the lumpectomy PTV volume covered by 100.4% in prone plans, 98.5% in AveIP plans, and 99.3% in DIBH plans (p=0.7). Conclusions Prone positioning provides dosimetric advantages as compared to DIBH. When infection risks are considered as in the current coronavirus disease 2019 (COVID-19) pandemic, prone plans have advantages in reducing the risk of disease transmission. In instances where prone positioning is not feasible, obtaining an AveIP simulation may be useful in more accurately assessing heart and lung toxicity and informing a risk/benefit discussion of DIBH vs free breath-hold techniques.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Idioma:
En
Revista:
Cureus
Año:
2021
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos