Efficacy of Monitoring Platelet Function by an Automated PL-12 Analyzer During the Treatment of Acute Cerebral Infarction With Antiplatelet Medicine.
Yue, Cen; Lin, Zhiwei; Lu, Congxia; Chen, Hanshui.
Afiliación
  • Yue C; Department of Neurology, The First Affiliated Hospital of Xiamen University, Xiamen, Fujian, China.
  • Lin Z; Department of Neurology, The First Hospital of Putian City, Putian, Fujian, China.
  • Lu C; Department of Neurology, The First Affiliated Hospital of Xiamen University, Xiamen, Fujian, China.
  • Chen H; Department of Neurology, The First Affiliated Hospital of Xiamen University, Xiamen, Fujian, China.
Clin Appl Thromb Hemost ; 27: 10760296211001119, 2021.
Article en En | MEDLINE | ID: mdl-33749312
ABSTRACT

METHODS:

All participants were administered with oral aspirin (100 mg/d) for 7 days. Blood samples were then collected and platelet function evaluated by an automated PL-12 analyzer, TEG, and the platelet count drop method. We found that platelet counts determined by the traditional platelet drop method were significantly lower in the PL-12 sensitive group and significantly higher in the PL-12 insensitive group (P < 0.05). Furthermore, MAR measured by PL-12 was positively correlated with the MA values determined by TEG and the platelet drop method (r = 0.322, r = 0.036, respectively, P < 0.05), More importantly, the PL-12 analyzer showed the largest AUC (0.748) with a sensitivity of 87.4% and a specificity of 57.4%, indicating PL-12 analyzer using in platelet aggregation evaluation of ACI patients more credibly and accuracy. Additionally, genetic analysis showed that the polymorphic of A-allele in the PEAR1 (rs12041331) gene was significantly increased in the PL-12 sensitive group rather than in the PL-12 insensitive group (P < 0.05), suggesting the predictive value of PL-12 analyzer for the prognosis of ACI patients was superior to the other methods tested herein. Our analyses demonstrate that PL-12 analysis offer a new superior technology for monitoring antiplatelet drug efficacy and for clinical prognosis of ACI patients, which has the advantages of simplicity, speed, and automation in platelet aggregation measurement.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pruebas de Función Plaquetaria / Tromboelastografía / Inhibidores de Agregación Plaquetaria / Infarto Cerebral / Aspirina Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Appl Thromb Hemost Asunto de la revista: ANGIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pruebas de Función Plaquetaria / Tromboelastografía / Inhibidores de Agregación Plaquetaria / Infarto Cerebral / Aspirina Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Appl Thromb Hemost Asunto de la revista: ANGIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China