Your browser doesn't support javascript.
loading
A signal-on photoelectrochemical aptasensor for chloramphenicol assay based on 3D self-supporting AgI/Ag/BiOI Z-scheme heterojunction arrays.
Zhu, Jian-Hong; Feng, Yi-Ge; Wang, Ai-Jun; Mei, Li-Ping; Luo, Xiliang; Feng, Jiu-Ju.
Afiliación
  • Zhu JH; College of Geography and Environmental Sciences, College of Chemistry and Life Sciences, Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Zhejiang Normal University, Jinhua, 321004, China.
  • Feng YG; College of Geography and Environmental Sciences, College of Chemistry and Life Sciences, Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Zhejiang Normal University, Jinhua, 321004, China.
  • Wang AJ; College of Geography and Environmental Sciences, College of Chemistry and Life Sciences, Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Zhejiang Normal University, Jinhua, 321004, China.
  • Mei LP; College of Geography and Environmental Sciences, College of Chemistry and Life Sciences, Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Zhejiang Normal University, Jinhua, 321004, China. Electronic address: mei.lp@zjnu.edu.cn.
  • Luo X; Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Sciences, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China.
  • Feng JJ; College of Geography and Environmental Sciences, College of Chemistry and Life Sciences, Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Zhejiang Normal University, Jinhua, 321004, China. Electronic address: jjfeng@zjnu.cn.
Biosens Bioelectron ; 181: 113158, 2021 Jun 01.
Article en En | MEDLINE | ID: mdl-33752026
Severe challenges are still remained for development of highly sensitive, selective and stable photoelectrochemical (PEC) sensing technology, albeit with its broad application for chloramphenicol (CAP) detection. Herein, a novel "signal-on" PEC aptasensor was fabricated based on a 3D self-supporting Z-scheme AgI/Ag/BiOI heterojunction arrays subtly integrated with in-situ formed biocatalytic precipitation (BCP) for highly sensitive and selective determination of CAP. Impressively, the HRP modified CAP aptamer (HRP-CAP aptamer) was released from the electrode by its strong affinity to the introduced CAP, and gradually terminated the BCP reaction, in turn recovering the photocurrent. By virtues of the 3D self-supporting AgI/Ag/BiOI Z-scheme heterojunction arrays and BCP signal amplification strategy, the resultant PEC sensor exhibited a wide linear range of 2-250 nM with a limit of detection (LOD) as low as 0.226 nM (S/N = 3). This work opens a new avenue for design of PEC aptasensing strategy and exhibits the marvelous potential in bioanalysis of environmental samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Aptámeros de Nucleótidos Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Aptámeros de Nucleótidos Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China Pais de publicación: Reino Unido