Your browser doesn't support javascript.
loading
Broadly neutralizing HIV-1 antibody reactivity in HIV tests: implications for diagnostics.
Smith, Tara; Masciotra, Silvina; Luo, Wei; Sullivan, Vickie; Switzer, William M; Johnson, Jeffrey A; Heneine, Walid.
Afiliación
  • Smith T; Oak Ridge Institute for Science and Research, Oak Ridge, TN.
  • Masciotra S; ICF.
  • Luo W; Division of HIV/AIDS Prevention, National Center for HIV/AIDS, Viral Hepatitis, STD and TB Prevention, Centers for Disease Control and Prevention, Atlanta, GA, USA.
  • Sullivan V; Division of HIV/AIDS Prevention, National Center for HIV/AIDS, Viral Hepatitis, STD and TB Prevention, Centers for Disease Control and Prevention, Atlanta, GA, USA.
  • Switzer WM; Division of HIV/AIDS Prevention, National Center for HIV/AIDS, Viral Hepatitis, STD and TB Prevention, Centers for Disease Control and Prevention, Atlanta, GA, USA.
  • Johnson JA; Division of HIV/AIDS Prevention, National Center for HIV/AIDS, Viral Hepatitis, STD and TB Prevention, Centers for Disease Control and Prevention, Atlanta, GA, USA.
  • Heneine W; Division of HIV/AIDS Prevention, National Center for HIV/AIDS, Viral Hepatitis, STD and TB Prevention, Centers for Disease Control and Prevention, Atlanta, GA, USA.
AIDS ; 35(10): 1561-1565, 2021 08 01.
Article en En | MEDLINE | ID: mdl-33756512
ABSTRACT

OBJECTIVE:

Passive immunization with broadly neutralizing antibodies (bNAbs) is under evaluation for HIV prevention. BNAbs target gp120 or gp41, two HIV envelope antigens commonly present in diagnostic tests. Depending on bNAb type and dose administered to humans, serum levels can reach nearly 1 mg/ml and wane over several weeks to months. We investigated the reactivity of bNAbs in HIV serological tests to inform diagnostic testing practices for persons treated with these products. DESIGN AND

METHODS:

The antigp120 bNAbs VRCO1, PGT121, PGT145, 3BNC117, 10-1074 and N6 and antigp41 bNAbs 10E8 and 10E8v4 were tested with the laboratory-based Bio-Rad Ag/Ab Combo assay, the point-of-care single-use Determine Combo, OraQuick, Reveal G4, SureCheck, Uni-Gold, INSTI and DPP HIV-1/2 assays, and the supplemental Geenius and HIV-1 Western Blot assays.

RESULTS:

At 1 mg/ml, all bNAbs were nonreactive in four screening tests. OraQuick, SureCheck, Reveal G4 and INSTI detected at least two bNAbs each; SureCheck exhibited reactivity to six bNAbs. Geenius was HIV-1 indeterminate (gp160+) with all bNAbs except PGT121, which was HIV antibody-negative. HIV-1 Western Blot was indeterminate (gp41+/gp160+) with 10E8 and 10E8v4 and negative with the remaining bNAbs. There was no correlation between the test antigen construct(s) and bNAb reactivity.

CONCLUSION:

We identified a laboratory-based Ag/Ab EIA and three single-use rapid HIV tests that are nonreactive against a panel of bNAbs supporting some diagnostic tests can distinguish HIV-1 infection events among persons receiving bNAb immunoprophylaxis. Evaluation of HIV diagnostic tests prior to clinical use may identify suitable serologic assays for persons administered bNAbs.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: AIDS Asunto de la revista: SINDROME DA IMUNODEFICIENCIA ADQUIRIDA (AIDS) Año: 2021 Tipo del documento: Article País de afiliación: Túnez

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: AIDS Asunto de la revista: SINDROME DA IMUNODEFICIENCIA ADQUIRIDA (AIDS) Año: 2021 Tipo del documento: Article País de afiliación: Túnez
...