A study of dose indicators during intra-arterial catheter implantation for liver chemotherapy.
Izaaryene, Jean; Golin, Melissa; Daidj, Nassima; Piana, Gilles; Ferre, Marjorie.
Afiliación
  • Izaaryene J; Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France.
  • Golin M; Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France.
  • Daidj N; Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France.
  • Piana G; Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France.
  • Ferre M; Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France.
J Radiol Prot ; 41(3)2021 Aug 18.
Article en En | MEDLINE | ID: mdl-33827058
ABSTRACT
The aim of the present study was to describe patient dose indicator levels during intra-arterial catheter (IAC) implantation for liver chemotherapy, and to determine factors affecting the dose indicators. Between January 2017 and January 2019, 61 patients with hepatic metastases from colorectal cancer were retrospectively included. Interventions were carried out in a standardised manner by three experienced radiologists on the same angiographic table without changes in protocol parameters. For each patient, clinical, radiological and dosimetry data were collected, including the air kerma area product (KAP), part of KAP due to the fluoroscopy and fluoroscopy time (FT), total kerma at the reference interventional point and peak skin dose (PSD). Local dose reference levels (RLs) were determined as the third quartile of the patient dose distributions. Univariate and multivariate analysis of factors affecting dose indicators was performed. The mean KAP was 111 Gy cm2, the mean reference point air kerma (Ka,r) was 648 mGy, the mean PSD was 613 mGy, and the mean FT was 3190 s (62% of the KAP). The mean cone beam computed tomography dose was 37.3 ± 11.8 Gy cm2, which accounted for 37% of the KAP. The RL could be proposed taking into account the third quartiles (KAP = 164.6 Gy cm2, Ka,r = 904.5 mGy, FT = 4011 s and standard deviation = 772.7 mGy). The factors affecting dose indicators were related to the patients (sex, cardiovascular risk factors, weight, body mass index), to the vascular anatomies (coeliac trunk angulation) and to the procedures (number of embolised arteries). This study allowed a better understanding of dose indicators and factors affecting these indicators during the implantation of IACs for hepatic chemotherapy, which is a long and difficult procedure. Local dose RLs were determined. Multicentre, multi-equipment studies are necessary.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arterias / Radiografía Intervencional Tipo de estudio: Guideline / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Radiol Prot Asunto de la revista: RADIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arterias / Radiografía Intervencional Tipo de estudio: Guideline / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Radiol Prot Asunto de la revista: RADIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Francia