Your browser doesn't support javascript.
loading
Dimensions of pes anserinus of the lower extremity, an anatomical study with its surgical implications.
Vadgaonkar, Rajanigandha; Prameela, M D; Kumar, Chettiar Ganesh; Blossom, Vandana; Tonse, Mamatha; Murlimanju, B V; Pai, Mangala M; Prabhu, Latha V.
Afiliación
  • Vadgaonkar R; Department of Anatomy, Kasturba Medical College, Mangalore, India.
  • Prameela MD; Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Kumar CG; Department of Anatomy, Kasturba Medical College, Mangalore, India.
  • Blossom V; Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Tonse M; Department of Anatomy, Kasturba Medical College, Mangalore, India.
  • Murlimanju BV; Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Pai MM; Department of Anatomy, Kasturba Medical College, Mangalore, India.
  • Prabhu LV; Manipal Academy of Higher Education, Manipal, Karnataka, India.
Anat Cell Biol ; 54(2): 178-183, 2021 Jun 30.
Article en En | MEDLINE | ID: mdl-33827991
ABSTRACT
The reconstructive surgeries utilize pes anserinus (PA) tendons, because of their lesser post-operative clinical deficits and donor site morbidity. These surgeries require anatomical knowledge about the extent of PA formation. The goal of this study was to determine the length and width of the PA formation. The objectives were to measure the distance of its upper limit, lower limit, and vertical distance from the tibial tuberosity (TT). The present descriptive cross sectional study included 53 embalmed cadaveric lower extremities. The upper and lower limits of PA were exposed with the careful dissection. Measurements of the dimensions were performed with the help of a digital vernier caliper (Mitutoyo Co., Kanagawa, Japan). The PA length, width, distance of its upper limit, lower limit, and vertical distance of it from the TT were 47.4±13.3 mm, 37.3±7.2 mm, 47.6±12.5 mm, 54.6±10.4 mm, and 39.1±14.2 mm, respectively over the right extremity. The same measurements were 46.3±14.7 mm, 39.1±9.4 mm, 39.1±5.9 mm, 49.5±8.2 mm, and 36.4±12.1 mm, respectively for the left extremity. The extent of PA was observed to be extremely variable. The preoperative knowledge about the dimensions of PA will help the plastic and orthopedic surgeon put the accurate skin incision, decreasing the donor site morbidity and biomechanical instability of the PA grafts. We suggest that, preoperative ultrasound measurement of the PA may help the operating surgeon to prevent the complications like injury to the infrapatellar branch of saphenous nerve.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies Idioma: En Revista: Anat Cell Biol Año: 2021 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies Idioma: En Revista: Anat Cell Biol Año: 2021 Tipo del documento: Article País de afiliación: India