Your browser doesn't support javascript.
loading
The Korean Version of the Fugl-Meyer Assessment: Reliability and Validity Evaluation.
Kim, Tae-Lim; Hwang, Sung Hwan; Lee, Wang Jae; Hwang, Jae Woong; Cho, Inyong; Kim, Eun-Hye; Lee, Jung Ah; Choi, Yujin; Park, Jin Ho; Shin, Joon-Ho.
Afiliación
  • Kim TL; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
  • Hwang SH; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
  • Lee WJ; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
  • Hwang JW; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
  • Cho I; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
  • Kim EH; Department of Clinical Rehabilitation Research, Korea National Rehabilitation Research Institute, Seoul, Korea.
  • Lee JA; Department of Clinical Rehabilitation Research, Korea National Rehabilitation Research Institute, Seoul, Korea.
  • Choi Y; Department of Clinical Rehabilitation Research, Korea National Rehabilitation Research Institute, Seoul, Korea.
  • Park JH; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
  • Shin JH; Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea.
Ann Rehabil Med ; 45(2): 83-98, 2021 Apr.
Article en En | MEDLINE | ID: mdl-33849084
ABSTRACT

OBJECTIVE:

To systematically translate the Fugl-Meyer Assessment (FMA) into a Korean version of the FMA (K-FMA).

METHODS:

We translated the original FMA into the Korean version with three translators and a translation committee, which included physiatrists, physical therapists, and occupational therapists. Based on a test-retest method, each of 31 patients with stroke was assessed by two evaluators twice, once on recruitment, and again after a week. Analysis of intra- and inter-rater reliabilities was performed using the intra-class correlation coefficient, whereas validity was analysed using Pearson correlation test along with the Motricity Index (MI), Motor Assessment Scale (MAS), and Berg Balance Scale (BBS).

RESULTS:

The intra- and inter-rater reliabilities were significant for the total score, and good to excellent reliability was noted in all domains except for the joint range of motion of the lower extremity domain of the K-FMA. The MI and MAS scores were significantly correlated with all domains, all with p<0.01. The results for the MI ranged from r=0.639 to r=0.891 and those for the MAS from r=0.339 to r=0.555. However, the BBS was not significantly correlated with any domain, as the K-FMA lacks balance evaluation items.

CONCLUSION:

The K-FMA was found to have high reliability and validity. Additionally, the newly developed manual for the K-FMA may help minimise errors that can occur during evaluation and improve the reliability of motor function evaluation.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: Ann Rehabil Med Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: Ann Rehabil Med Año: 2021 Tipo del documento: Article
...