Your browser doesn't support javascript.
loading
Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models.
León-Muñoz, Vicente J; Parrinello, Andrea; Manca, Silvio; Galloni, Gianluca; López-López, Mirian; Martínez-Martínez, Francisco; Santonja-Medina, Fernando.
Afiliación
  • León-Muñoz VJ; Department of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain.
  • Parrinello A; Product Management Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland.
  • Manca S; Patient Matched Technology Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland.
  • Galloni G; Patient Matched Technology Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland.
  • López-López M; Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Avenida Central, 7, Edificio Habitamia, Espinardo, 30100 Murcia, Spain.
  • Martínez-Martínez F; Department of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain.
  • Santonja-Medina F; Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia, 30100 Murcia, Spain.
J Clin Med ; 10(7)2021 Apr 01.
Article en En | MEDLINE | ID: mdl-33916110
ABSTRACT
There have been remarkable advances in knee replacement surgery over the last few decades. One of the concerns continues to be the accuracy in achieving the desired alignment. Patient-specific instrumentation (PSI) was developed to increase component placement accuracy, but the available evidence is not conclusive. Our study aimed to determine a PSI system's three-dimensional accuracy on 3D virtual models obtained by post-operative computed tomography. We compared the angular placement values of 35 total knee arthroplasties (TKAs) operated within a year obtained with the planned ones, and we analyzed the possible relationships between alignment and patient-reported outcomes. The mean (SD) discrepancies measured by two experienced engineers to the planned values observed were 1.64° (1.3°) for the hip-knee-ankle angle, 1.45° (1.06°) for the supplementary angle of the femoral lateral distal angle, 1.44° (0.97°) for the proximal medial tibial angle, 2.28° (1.78°) for tibial slope, 0.64° (1.09°) for femoral sagittal flexion, and 1.42° (1.06°) for femoral rotation. Neither variables related to post-operative alignment nor the proportion of change between pre-and post-operative alignment influenced the patient-reported outcomes. The evaluated PSI system's three-dimensional alignment analysis showed a statistically significant difference between the angular values planned and those obtained. However, we did not find a relevant effect size, and this slight discrepancy did not impact the clinical outcome.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Aspecto: Patient_preference Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Aspecto: Patient_preference Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article País de afiliación: España