Your browser doesn't support javascript.
loading
Sutureless intrascleral fixation using a uniquely designed intraocular lens.
Colantuono, D; Seknazi, D; Miere, A; Amoroso, F; Glacet-Bernard, A; Souied, E H.
Afiliación
  • Colantuono D; Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, Université Paris Est, 40, avenue Verdun, 94010 Créteil, France. Electronic address: colantuono.donato88@gmail.com.
  • Seknazi D; Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, Université Paris Est, 40, avenue Verdun, 94010 Créteil, France.
  • Miere A; Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, Université Paris Est, 40, avenue Verdun, 94010 Créteil, France.
  • Amoroso F; Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, Université Paris Est, 40, avenue Verdun, 94010 Créteil, France.
  • Glacet-Bernard A; Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, Université Paris Est, 40, avenue Verdun, 94010 Créteil, France.
  • Souied EH; Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, Université Paris Est, 40, avenue Verdun, 94010 Créteil, France.
J Fr Ophtalmol ; 44(7): 957-961, 2021 Sep.
Article en En | MEDLINE | ID: mdl-34154871
ABSTRACT
We report our experience in the surgical technique of sutureless intrascleral posterior chamber intraocular lens (PC IOL) fixation in patients with insufficient capsular support using a uniquely designed, foldable, acrylic Carlevale IOL. It is specifically designed for sutureless scleral fixation and is equipped with a small plug attached to each of two haptics to anchor the lens to the sclera with a self-retaining mechanism. This surgery does not require creation of a scleral tunnel or transscleral exposure or excessive manipulation of the haptics. The harpoon-like plugs provide great stability to this implant, which can be injected through a 2.2mm incision. The characteristics of this IOL and the relative simplicity of this implantation technique makes it widely applicable in aphakic patients after previous complicated cataract surgery.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Implantación de Lentes Intraoculares / Lentes Intraoculares Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Fr Ophtalmol Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Implantación de Lentes Intraoculares / Lentes Intraoculares Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Fr Ophtalmol Año: 2021 Tipo del documento: Article