Hypercoagulability Evaluation in Antiphospholipid Syndrome without Anticoagulation Treatment with Thrombin Generation Assay: A Preliminary Study.
Billoir, Paul; Miranda, Sébastien; Levesque, Herve; Benhamou, Ygal; Le Cam Duchez, Véronique.
Afiliación
  • Billoir P; Vascular Hemostasis Unit, Rouen University Hospital, Normandie University, UNIROUEN, INSERM U1096, F 76000 Rouen, France.
  • Miranda S; Vascular and Thrombosis Unit, Department of Internal Medicine, Rouen University Hospital, Normandie University, UNIROUEN, INSERM U1096, F 76000 Rouen, France.
  • Levesque H; Vascular and Thrombosis Unit, Department of Internal Medicine, Rouen University Hospital, Normandie University, UNIROUEN, INSERM U1096, F 76000 Rouen, France.
  • Benhamou Y; Vascular and Thrombosis Unit, Department of Internal Medicine, Rouen University Hospital, Normandie University, UNIROUEN, INSERM U1096, F 76000 Rouen, France.
  • Le Cam Duchez V; Vascular Hemostasis Unit, Rouen University Hospital, Normandie University, UNIROUEN, INSERM U1096, F 76000 Rouen, France.
J Clin Med ; 10(12)2021 Jun 21.
Article en En | MEDLINE | ID: mdl-34205545
ABSTRACT
Antiphospholipid syndrome (APS) is associated with thrombotic events (tAPS) and/or obstetrical morbidity (oAPS), with persisting antiphospholipid antibodies (aPL). Despite an update of aPL in 2006, several patients had typical clinical events without the classical biological criteria. The aim of our study was to evaluate the hypercoagulability state with both thrombin generation (TG) profiles and activated protein C resistance (aPCR) in different types of APS.

METHODS:

We retrospectively included 41 patients with Sydney criteria classification (tAPS, oAPS) and no clinical manifestation of APS with persistent aPL (biological APS). A thrombin generation assay was performed with a Fluoroskan Ascent fluorometer in platelet-poor plasma (PPP). Activated protein C resistance was measured as a ratio ETP+aPC/ETP-aPC × 100.

RESULTS:

Thrombotic APS and oAPS had an increase of global thrombin generation (ETPcontrol = 808 nM.min (756-853) vs. 1265 nM.min (956-1741) and 1863 nM.min (1434-2080), respectively) (Peakcontrol = 78 nM (74-86) vs. 153 nM (109-215) and 254 nM.min (232-289), respectively). Biological APS had only a lag time increase (Tcontrol = 4.89 ± 1.65 min vs. 13.6 ± 3.9 min). An increased aPCR was observed in tAPS (52.7 ± 16.4%), oAPS (64.1 ± 14.6%) as compared to the control group (27.2 ± 13.8%).

CONCLUSION:

Our data suggest an increase of thrombin generation in thrombotic and obstetrical APS and no hypercoagulable states in patients with biological APS. The study of a prospective and a larger controlled cohort could determine the TGA useful for APS monitoring and could confirm an aPCR evaluation in PPP.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article País de afiliación: Francia