Your browser doesn't support javascript.
loading
Effects of External Laryngeal Manipulation on Cervical Spine Motion during Videolaryngoscopic Intubation under Manual In-Line Stabilization: A Randomized Crossover Trial.
Kim, Yoon Jung; Hur, Chahnmee; Yoon, Hyun-Kyu; Lee, Hyung-Chul; Park, Hee-Pyoung; Oh, Hyongmin.
Afiliación
  • Kim YJ; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 03080, Korea.
  • Hur C; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 03080, Korea.
  • Yoon HK; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 03080, Korea.
  • Lee HC; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 03080, Korea.
  • Park HP; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 03080, Korea.
  • Oh H; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 03080, Korea.
J Clin Med ; 10(13)2021 Jun 30.
Article en En | MEDLINE | ID: mdl-34208825
ABSTRACT
We hypothesized that external laryngeal manipulation would reduce cervical spine motion during video laryngoscopic intubation under manual in-line stabilization by reducing the force required to lift the videolaryngoscope. In this randomized crossover trial, 27 neurointerventional patients underwent two consecutive videolaryngoscopic intubation attempts under manual in-line stabilization. External laryngeal manipulation was applied to all patients in either the first or second attempt. In the second attempt, we tried to reproduce the percentage of glottic opening score obtained in the first attempt. Primary outcomes were cervical spine motion during intubation at the occiput-C1, C1-C2, and C2-C5 segments. The intubation success rate (secondary outcome measure) was recorded. Cervical spine motion during intubation at the occiput-C1 segment was significantly smaller with than without external laryngeal manipulation (7.4° ± 4.6° vs. 11.5° ± 4.8°, mean difference -4.1° (98.33% confidence interval -5.8° to -2.3°), p < 0.001), showing a reduction of 35.7%. Cervical spine motion during intubation at the other segments was not significantly different with versus without external laryngeal manipulation. All intubations were achieved successfully regardless of the application of external laryngeal manipulation. External laryngeal manipulation is a useful method to reduce upper cervical spine motion during videolaryngoscopic intubation under manual in-line stabilization.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article