Fast-ion Dα spectroscopy diagnostic at KSTAR.
Yoo, J W; Kim, J; Lee, M W; Kang, J; Ko, W-H; Oh, S G; Ko, J; Lee, J H; Nam, Y U; Jung, L; Park, B H; Yoon, S W.
Afiliación
  • Yoo JW; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Kim J; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Lee MW; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Kang J; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Ko WH; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Oh SG; Ajou University, 206, World Cup-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do 16499, Republic of Korea.
  • Ko J; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Lee JH; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Nam YU; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Jung L; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Park BH; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
  • Yoon SW; Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea.
Rev Sci Instrum ; 92(4): 043504, 2021 Apr 01.
Article en En | MEDLINE | ID: mdl-34243446
ABSTRACT
A fast-ion Dα (FIDA) diagnostics system was installed for core and edge measurements on KSTAR. This system has two tangential FIDA arrays that cover both blue- and redshifted Dα lines (cold 656.09 nm) in active views along the neutral beam 1 A centerline. The spectral band is 647-662.5 nm, and it covers the Doppler shift of the emission from the maximum energy of the neutral beam (100 keV). A curved filter strip with a motorized stage adequately prevents saturation of the electron multiplying charge-coupled device signal by the cold Dα line from the plasma edge. From comparisons of the measured spectra and FIDASIM modeling code, the FIDA spectra are well matched quantitatively. Moreover, the first measurements show that the FIDA radiance agrees with the neutron rate in the time trace during external heating and perturbation. In addition, responses are observed in the core FIDA radiance during the edge-localized mode cycle.