Your browser doesn't support javascript.
loading
Evaluation of skin dose and skin toxicity in patients undergoing intraoperative radiotherapy for early breast cancer.
Wong, Jeannie Hsiu Ding; Zaili, Zainor; Abdul Malik, Rozita; Bustam, Anita Zarina; Saad, Marniza; Jamaris, Suniza; Mosiun, Joanne Aisha; Mohd Taib, Nur Aishah; Ung, Ngie Min; See, Mee-Hoong.
Afiliación
  • Wong JHD; Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Zaili Z; Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Abdul Malik R; Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Bustam AZ; Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Saad M; Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Jamaris S; Breast Surgery Unit, Department of Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Mosiun JA; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Mohd Taib NA; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Ung NM; Breast Surgery Unit, Department of Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • See MH; Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
J Appl Clin Med Phys ; 22(8): 139-147, 2021 Aug.
Article en En | MEDLINE | ID: mdl-34254425
PURPOSE: This study aims to evaluate in vivo skin dose delivered by intraoperative radiotherapy (IORT) and determine the factors associated with an increased risk of radiation-induced skin toxicity. METHODOLOGY: A total of 21 breast cancer patients who underwent breast-conserving surgery and IORT, either as IORT alone or IORT boost plus external beam radiotherapy (EBRT), were recruited in this prospective study. EBT3 film was calibrated in water and used to measure skin dose during IORT at concentric circles of 5 mm and 40 mm away from the applicator. For patients who also had EBRT, the maximum skin dose was estimated using the radiotherapy treatment planning system. Mid-term skin toxicities were evaluated at 3 and 6 months post-IORT. RESULTS: The average skin dose at 5 mm and 40 mm away from the applicator was 3.07 ± 0.82 Gy and 0.99 ± 0.28 Gy, respectively. Patients treated with IORT boost plus EBRT received an additional skin dose of 41.07 ± 1.57 Gy from the EBRT component. At 3 months post-IORT, 86% of patients showed no evidence of skin toxicity. However, the number of patients suffering from skin toxicity increased from 15% to 38% at 6 months post-IORT. We found no association between the IORT alone or with the IORT boost plus EBRT and skin toxicity. Older age was associated with increased risk of skin toxicities. A mathematical model was derived to predict skin dose. CONCLUSION: EBT3 film is a suitable dosimeter for in vivo skin dosimetry in IORT, providing patient-specific skin doses. Both IORT alone and IORT boost techniques resulted in similar skin toxicity rates.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos por Radiación / Neoplasias de la Mama Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2021 Tipo del documento: Article País de afiliación: Malasia Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos por Radiación / Neoplasias de la Mama Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2021 Tipo del documento: Article País de afiliación: Malasia Pais de publicación: Estados Unidos