Your browser doesn't support javascript.
loading
Assessment of the viscoelastic mechanical properties of the porcine optic nerve head using micromechanical testing and finite element modeling.
Safa, Babak N; Read, A Thomas; Ethier, C Ross.
Afiliación
  • Safa BN; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA.
  • Read AT; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA.
  • Ethier CR; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA. Electronic address: ross.ethier@bme.gatech.edu.
Acta Biomater ; 134: 379-387, 2021 10 15.
Article en En | MEDLINE | ID: mdl-34274532
ABSTRACT
Optic nerve head (ONH) biomechanics is centrally involved in the pathogenesis of glaucoma, a blinding ocular condition often characterized by elevation and fluctuation of the intraocular pressure and resulting loads on the ONH. Further, tissue viscoelasticity is expected to strongly influence the mechanical response of the ONH to mechanical loading, yet the viscoelastic mechanical properties of the ONH remain unknown. To determine these properties, we conducted micromechanical testing on porcine ONH tissue samples, coupled with finite element modeling based on a mixture model consisting of a biphasic material with a viscoelastic solid matrix. Our results provide a detailed description of the viscoelastic properties of the porcine ONH at each of its four anatomical quadrants (i.e., nasal, superior, temporal, and inferior). We showed that the ONH's viscoelastic mechanical response can be explained by a dual mechanism of fluid flow and solid matrix viscoelasticity, as is common in other soft tissues. We obtained porcine ONH properties as follows matrix Young's modulus E=1.895[1.056,2.391] kPa (median [min., max.]), Poisson's ratio ν=0.142[0.060,0.312], kinetic time-constant τ=214[89,921] sec, and hydraulic permeability k=3.854×10-1[3.457×10-2,9.994×10-1] mm4/(N.sec). These values can be used to design and fabricate physiologically appropriate ex vivo test environments (e.g., 3D cell culture) to further understand glaucoma pathophysiology. STATEMENT OF

SIGNIFICANCE:

Optic nerve head (ONH) biomechanics is an important aspect of the pathogenesis of glaucoma, the leading cause of irreversible blindness. The ONH experiences time-varying loads, yet the viscoelastic behavior of this tissue has not been characterized. Here, we measure the time-dependent response of the ONH in porcine eyes and use mechanical modeling to provide time-dependent mechanical properties of the ONH. This information allows us to identify time-varying stimuli in vivo which have timescales matching the characteristic response times of the ONH, and can also be used to design and fabricate ex vivo 3D cultures to study glaucoma pathophysiology in a physiologically relevant environment, enabling the discovery of new generations of glaucoma medications focusing on neuroprotection.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Glaucoma Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Acta Biomater Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Glaucoma Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Acta Biomater Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos