Your browser doesn't support javascript.
loading
Development of an LC-MS/MS method for quantification of 3-chloro-L-tyrosine as a candidate marker of chlorine poisoning.
Nishio, Tadashi; Toukairin, Yoko; Hoshi, Tomoaki; Arai, Tomomi; Nogami, Makoto.
Afiliación
  • Nishio T; Department of Legal Medicine, Teikyo University School of Medicine, 2-11-1, Kaga, Itabashi-ku, Tokyo 173-8605, Japan. Electronic address: tnishio@med.teikyo-u.ac.jp.
  • Toukairin Y; Department of Legal Medicine, Teikyo University School of Medicine, 2-11-1, Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
  • Hoshi T; Department of Legal Medicine, Teikyo University School of Medicine, 2-11-1, Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
  • Arai T; Department of Legal Medicine, Teikyo University School of Medicine, 2-11-1, Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
  • Nogami M; Department of Legal Medicine, Teikyo University School of Medicine, 2-11-1, Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
Leg Med (Tokyo) ; 53: 101939, 2021 Nov.
Article en En | MEDLINE | ID: mdl-34303936
ABSTRACT
A simple and sensitive liquid chromatography coupled with electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method for the determination of 3-chloro-L-tyrosine (Cl-Tyr) was developed and validated. For sample preparation, 50 µL of the body fluids or tissue extracts were processed by protein precipitation followed by the derivatization with dansyl chloride. The calibration curve was linear over the concentration range of 2.0-200 ng/mL blood or 4.0-400 ng/g tissue. Our method allowed the reproducible and accurate quantification. That is, the intra- and inter-assay coefficients of variation were below 7.73 and 6.94%, respectively in both the blood and lung. We applied the developed method to the analysis of Cl-Tyr in the human autopsy samples, which were suspected of chlorine poisoning, and detected 55.2 ng/mL and 206.6 ng/g Cl-Tyr in left heart blood and lung, respectively. Furthermore, in more than 20 autopsy samples, which were obtained from other causes of death including burn, drowning, hanging, internal disease, trauma and drug poisoning, Cl-Tyr was almost not detected in their both body fluids and organ tissues. In conclusion, the data here reported demonstrate that the LC/ESI-MS/MS method allows the Cl-Tyr in the autopsy samples and that chlorine exposure strongly affects its level, providing a basis for novel identification tool of chlorine poisoning.