Closed-loop multibody kinematic optimization coupled with double calibration improves scapular kinematic estimates in asymptomatic population.
Blache, Y; Degot, M; Duprey, S; Begon, M; Rogowski, I.
Afiliación
  • Blache Y; Univ Lyon, Université Claude Bernard Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité, EA 7424, F-69622 Villeurbanne, France. Electronic address: Yoann.blache@univ-lyon1.fr.
  • Degot M; Univ Lyon, Université Claude Bernard Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité, EA 7424, F-69622 Villeurbanne, France.
  • Duprey S; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France.
  • Begon M; École de Kinésiologie et de Sciences de l'Activité Physique, Université de Montréal, Canada.
  • Rogowski I; Univ Lyon, Université Claude Bernard Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité, EA 7424, F-69622 Villeurbanne, France.
J Biomech ; 126: 110653, 2021 09 20.
Article en En | MEDLINE | ID: mdl-34343862
ABSTRACT
Non-invasive methods still need to better estimate scapular kinematics because of soft tissue artifact issue. This study aimed to develop and assess new procedures to estimate scapular kinematics by combining closed kinematic chain optimization and double calibration. Sixteen healthy volunteers performed static postures mimicking analytical and daily living movements. Scapulo-thoracic angles were computed either with a scapula locator (Ref), or with a closed-loop multibody kinematic optimization (Ell) or with double calibration involving linear (DClin), exponential (DCexp) or logarithmic (DClog) correction. Double calibration corrections enforced scapulo-thoracic angles to be the same than those measured with Ref at the end of the movement performed. DClin and DClog significantly (p < 0.01) reduced scapulo-thoracic misorientation for at least the second third of the movement with averaged improvement ranging from 9° to 32°. Moreover, for arm elevation in the sagittal plane, internal rotations and mimicking hair combing, the beneficial effect of DClin and DClog propagates up to half of the movement. To conclude, when a kinematic chain is required, coupling double calibration (using either linear or logarithmic correction), to a closed-loop multibody kinematic optimization is an efficient and fast method in regard with improvement in scapular kinematic estimates in healthy population.