Your browser doesn't support javascript.
loading
Fully Automated Colorimetric Analysis of the Optic Nerve Aided by Deep Learning and Its Association with Perimetry and OCT for the Study of Glaucoma.
Gonzalez-Hernandez, Marta; Gonzalez-Hernandez, Daniel; Perez-Barbudo, Daniel; Rodriguez-Esteve, Paloma; Betancor-Caro, Nisamar; Gonzalez de la Rosa, Manuel.
Afiliación
  • Gonzalez-Hernandez M; INSOFT S.L., 25 de Julio, 34, 38004 Santa Cruz de Tenerife, Spain.
  • Gonzalez-Hernandez D; Ophthalmology Department, Hospital Universitario de Canarias, Carretera Ofra s/n, 38320 San Cristobal de La Laguna, Spain.
  • Perez-Barbudo D; INSOFT S.L., 25 de Julio, 34, 38004 Santa Cruz de Tenerife, Spain.
  • Rodriguez-Esteve P; INSOFT S.L., 25 de Julio, 34, 38004 Santa Cruz de Tenerife, Spain.
  • Betancor-Caro N; Facultad de Ciencias de la Salud, Universidad de La Laguna, C/Sta, María Soledad s/n, 38200 San Cristobal de La Laguna, Spain.
  • Gonzalez de la Rosa M; Facultad de Ciencias de la Salud, Universidad de La Laguna, C/Sta, María Soledad s/n, 38200 San Cristobal de La Laguna, Spain.
J Clin Med ; 10(15)2021 Jul 22.
Article en En | MEDLINE | ID: mdl-34362014
ABSTRACT

BACKGROUND:

Laguna-ONhE is an application for the colorimetric analysis of optic nerve images, which topographically assesses the cup and the presence of haemoglobin. Its latest version has been fully automated with five deep learning models. In this paper, perimetry in combination with Laguna-ONhE or Cirrus-OCT was evaluated.

METHODS:

The morphology and perfusion estimated by Laguna ONhE were compiled into a "Globin Distribution Function" (GDF). Visual field irregularity was measured with the usual pattern standard deviation (PSD) and the threshold coefficient of variation (TCV), which analyses its harmony without taking into account age-corrected values. In total, 477 normal eyes, 235 confirmed, and 98 suspected glaucoma cases were examined with Cirrus-OCT and different fundus cameras and perimeters.

RESULTS:

The best Receiver Operating Characteristic (ROC) analysis results for confirmed and suspected glaucoma were obtained with the combination of GDF and TCV (AUC 0.995 and 0.935, respectively. Sensitivities 94.5% and 45.9%, respectively, for 99% specificity). The best combination of OCT and perimetry was obtained with the vertical cup/disc ratio and PSD (AUC 0.988 and 0.847, respectively. Sensitivities 84.7% and 18.4%, respectively, for 99% specificity).

CONCLUSION:

Using Laguna ONhE, morphology, perfusion, and function can be mutually enhanced with the methods described for the purpose of glaucoma assessment, providing early sensitivity.