Your browser doesn't support javascript.
loading
Rapid simultaneous acquisition of macromolecular tissue volume, susceptibility, and relaxometry maps.
Yu, Fang Frank; Huang, Susie Yi; Kumar, Ashwin; Witzel, Thomas; Liao, Congyu; Duval, Tanguy; Cohen-Adad, Julien; Bilgic, Berkin.
Afiliación
  • Yu FF; Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Huang SY; Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA.
  • Kumar A; Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Witzel T; Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • Liao C; Vanderbilt University, Nashville, Tennessee, USA.
  • Duval T; Q Bio, Inc., Redwood City, California, USA.
  • Cohen-Adad J; Radiological Sciences Laboratory, Stanford Medicine, Stanford, California, USA.
  • Bilgic B; Institute of Biomedical Engineering, Ecole Polytechnique de Montreal, Montreal, Quebec, Canada.
Magn Reson Med ; 87(2): 781-790, 2022 02.
Article en En | MEDLINE | ID: mdl-34480768
ABSTRACT

PURPOSE:

A major obstacle to the clinical implementation of quantitative MR is the lengthy acquisition time required to derive multi-contrast parametric maps. We sought to reduce the acquisition time for QSM and macromolecular tissue volume by acquiring both contrasts simultaneously by leveraging their redundancies. The joint virtual coil concept with GRAPPA (JVC-GRAPPA) was applied to reduce acquisition time further.

METHODS:

Three adult volunteers were imaged on a 3 Tesla scanner using a multi-echo 3D GRE sequence acquired at 3 head orientations. Macromolecular tissue volume, QSM, R2∗ , T1 , and proton density maps were reconstructed. The same sequence (GRAPPA R = 4) was performed in subject 1 with a single head orientation for comparison. Fully sampled data was acquired in subject 2, from which retrospective undersampling was performed (R = 6 GRAPPA and R = 9 JVC-GRAPPA). Prospective undersampling was performed in subject 3 (R = 6 GRAPPA and R = 9 JVC-GRAPPA) using gradient blips to shift k-space sampling in later echoes.

RESULTS:

Subject 1's multi-orientation and single-orientation macromolecular tissue volume maps were not significantly different based on RMSE. For subject 2, the retrospectively undersampled JVC-GRAPPA and GRAPPA generated similar results as fully sampled data. This approach was validated with the prospectively undersampled images in subject 3. Using QSM, R2∗ , and macromolecular tissue volume, the contributions of myelin and iron content to susceptibility were estimated.

CONCLUSION:

We have developed a novel strategy to simultaneously acquire data for the reconstruction of 5 intrinsically coregistered 1-mm isotropic resolution multi-parametric maps, with a scan time of 6 min using JVC-GRAPPA.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagen por Resonancia Magnética Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagen por Resonancia Magnética Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos