Your browser doesn't support javascript.
loading
Covalent cationic copolymer coatings allowing tunable electroosmotic flow for optimization of capillary electrophoretic separations.
Konásová, Renáta; Butnariu, Maria; Solínová, Veronika; Kasicka, Václav; Koval, Dusan.
Afiliación
  • Konásová R; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, 166 10, Prague 6, Czech Republic.
  • Butnariu M; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, 166 10, Prague 6, Czech Republic; Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 6, 128 43, Prague 2, Czech Republic.
  • Solínová V; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, 166 10, Prague 6, Czech Republic.
  • Kasicka V; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, 166 10, Prague 6, Czech Republic.
  • Koval D; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, 166 10, Prague 6, Czech Republic. Electronic address: koval@uochb.cas.cz.
Anal Chim Acta ; 1178: 338789, 2021 Sep 15.
Article en En | MEDLINE | ID: mdl-34482877
ABSTRACT
Electroosmotic flow (EOF) plays a pivotal role in optimization of capillary electrophoresis (CE) separations of (bio)molecules and (bio)particles. EOF velocity is directly related to analysis time, peak resolution and separation efficiency. Here, we report a concept of charged polymer coatings of the inner fused silica capillary wall, which allows anodic EOF with mobility ranging from 0 to ∼(30-40) × 10-9 m2V-1s-1. The capillary wall is modified by covalently bound cationic copolymer poly(acrylamide-co-(3-acrylamidopropyl)trimethylammonium chloride) (PAMAPTAC) containing variable ratio of the charged monomer in the 0-60 mol. % interval. The EOF mobility showed minor variability with composition of background electrolyte (BGE) and pH in the 2-10 interval. The coatings were evaluated by CE-UV and nanospray CE-MS in the counter-EOF arrangement for a series of basic drug molecules in acetic acid based acidic BGE. Tunable EOF velocity was demonstrated as a useful tool for optimization of peak resolution, separation efficiency and migration time of analytes. Electrostatic repulsion of positively charged capillary surface was shown as beneficial for suppression of analyte adsorption, notably for hydrophobic cationic analytes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Electroforesis Capilar / Electroósmosis Idioma: En Revista: Anal Chim Acta Año: 2021 Tipo del documento: Article País de afiliación: República Checa

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Electroforesis Capilar / Electroósmosis Idioma: En Revista: Anal Chim Acta Año: 2021 Tipo del documento: Article País de afiliación: República Checa