Early Bone Healing on Hydroxyapatite-Coated and Chemically-Modified Hydrophilic Implant Surfaces in an Ovine Model.
Ajami, Elnaz; Fu, Cong; Wen, Hai Bo; Bassett, Jeffrey; Park, Sun Jin; Pollard, Marie.
Afiliación
  • Ajami E; Department of Research and Development, Zimmer Biomet Dental, Palm Beach Gardens, FL 33410, USA.
  • Fu C; Department of Research and Development, Zimmer Biomet Dental, Palm Beach Gardens, FL 33410, USA.
  • Wen HB; Department of Research and Development, Zimmer Biomet Dental, Palm Beach Gardens, FL 33410, USA.
  • Bassett J; Department of Research and Development, Zimmer Biomet Dental, Palm Beach Gardens, FL 33410, USA.
  • Park SJ; Department of Research and Development, Zimmer Biomet Dental, Palm Beach Gardens, FL 33410, USA.
  • Pollard M; Department of Research and Development, Zimmer Biomet Dental, Palm Beach Gardens, FL 33410, USA.
Int J Mol Sci ; 22(17)2021 Aug 28.
Article en En | MEDLINE | ID: mdl-34502270
ABSTRACT
Implant topography affects early peri-implant bone healing by changing the osteoconduction rate in the surrounding biological environment. Implant surfaces have been designed to promote faster and stronger bone formation for rapid and stable prosthesis loading. Early peri-implant bone healing has been observed with a sandblasted, acid-etched implant that was chemically modified to be hydrophilic (cmSLA). The present study investigates whether early peri-implant bone healing extends to a rough surface implant with a high crystalline hydroxyapatite surface (TSV MP-1 HA). Three implants were randomly placed in porous trabecular bone within both medial femoral condyles of 10 sheep. Early peri-implant bone stability was measured at 3- and 6-weeks healing time following implant insertion. Results indicated a similar implant stability quotient between the implants at insertion and over time. The significant increase over time of reverse torque values with respect to insertion torque (p < 0.001) did not differ between the implants. However, the bone-to-implant contact of TSV MP-1 HA was significantly higher than that of cmSLA implants at 6 weeks (p < 0.01). These data validate previous findings of a hydrophilic implant surface and extend the observation of early osseointegration to a rough surface implant in porous trabecular bone.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Regeneración Ósea / Durapatita Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Int J Mol Sci Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Regeneración Ósea / Durapatita Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Int J Mol Sci Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos