Performance of the ESC 0/2h-algorithm using high-sensitivity cardiac troponin I in the early diagnosis of myocardial infarction.
Am Heart J
; 242: 132-137, 2021 12.
Article
en En
| MEDLINE
| ID: mdl-34508692
ABSTRACT
The 2020 guidelines of the European Society of Cardiology (ESC) recommend a novel ESC 0/2h-algorithm as the preferred alternative to the ESC 0/1h-algorithm in the early triage for rule-out and/or rule-in of Non-ST-segment-elevation myocardial infarction (NSTEMI). The aim was to prospectively validate the performance of the ESC 0/2h-algorithm using the high-sensitivity cardiac troponin I (hs-cTnI) assay (ARCHITECT) in an international, multicenter diagnostic study enrolling patients presenting with acute chest discomfort to the emergency department.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Algoritmos
/
Troponina I
/
Infarto del Miocardio
Tipo de estudio:
Clinical_trials
/
Diagnostic_studies
/
Guideline
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
Límite:
Humans
Idioma:
En
Revista:
Am Heart J
Año:
2021
Tipo del documento:
Article