Your browser doesn't support javascript.
loading
Analysis of short-chain bioactive peptides by unified chromatography-electrospray ionization mass spectrometry. Part I. Method development.
Molineau, Jérémy; Hamel, Yasmine; Hideux, Maria; Hennig, Philippe; Bertin, Sophie; Mauge, Fabien; Lesellier, Eric; West, Caroline.
Afiliación
  • Molineau J; University of Orleans, ICOA, CNRS UMR 7311, rue de Chartres, BP 6759, 45067 Orléans, France.
  • Hamel Y; University of Orleans, ICOA, CNRS UMR 7311, rue de Chartres, BP 6759, 45067 Orléans, France.
  • Hideux M; Institut de Recherches Servier, 11 Rue des Moulineaux, 92210 Suresnes, France.
  • Hennig P; Institut de Recherches Servier, 11 Rue des Moulineaux, 92210 Suresnes, France.
  • Bertin S; Institut de Recherches Servier, 11 Rue des Moulineaux, 92210 Suresnes, France.
  • Mauge F; Institut de Recherches Servier, 11 Rue des Moulineaux, 92210 Suresnes, France.
  • Lesellier E; University of Orleans, ICOA, CNRS UMR 7311, rue de Chartres, BP 6759, 45067 Orléans, France.
  • West C; University of Orleans, ICOA, CNRS UMR 7311, rue de Chartres, BP 6759, 45067 Orléans, France. Electronic address: caroline.west@univ-orleans.fr.
J Chromatogr A ; 1658: 462631, 2021 Nov 22.
Article en En | MEDLINE | ID: mdl-34700137
ABSTRACT
A method to analyse short-chain bioactive peptides (MW < 800 Da) and their impurities was developed with a unified chromatography (UC) analysis, including a wide mobile phase gradient ranging from supercritical fluid to near-liquid conditions, with UV and electrospray ionization mass spectrometry detection (ESI-MS). Four stationary phases and three mobile phase compositions were examined. Ten model peptides were first selected to identify the best operating conditions, including five linear tripeptides and five cyclic pentapeptides, with log P values ranging from -5.9 to 3.6, and including isomeric species. Derringer desirability functions were designed to identify optimal operating conditions based on 7 criteria, namely the number of peaks detected (including all impurities resolved), the proportion of the chromatogram occupied by target peaks, the least favourable resolution observed between the main peptide and impurities, peak shape features (asymmetry and peak width at half height), and finally the signal-to-noise ratio observed both with UV (210 nm) and ESI-MS in positive ionization mode. The optimum conditions were obtained on Ascentis Express OH5 stationary phase, with a mobile phase composed of carbon dioxide and methanol, comprising 2% water and 20 mM ammonium hydroxide. The final gradient program ranged from 5 to 80% co-solvent in CO2, with a reversed flow rate gradient ranging from 3.0 to 1.5 mL/min. Back-pressure was set at 120 bar and the column oven temperature at 60°C. Optimal conditions were applied to a large set of 76 peptides (34 linear tripeptides and 42 cyclic pentapeptides) and provided adequate scattering of the peaks in the retention space, together with some separation of isomeric species, particularly for the cyclic peptides.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masa por Ionización de Electrospray / Cromatografía con Fluido Supercrítico Tipo de estudio: Prognostic_studies Idioma: En Revista: J Chromatogr A Año: 2021 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masa por Ionización de Electrospray / Cromatografía con Fluido Supercrítico Tipo de estudio: Prognostic_studies Idioma: En Revista: J Chromatogr A Año: 2021 Tipo del documento: Article País de afiliación: Francia