Your browser doesn't support javascript.
loading
Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models.
Sezaki, Shunsuke; Otsuki, Shuhei; Ikeda, Kuniaki; Okuno, Nobuhiro; Okamoto, Yoshinori; Wakama, Hitoshi; Okayoshi, Tomohiro; Neo, Masashi.
Afiliación
  • Sezaki S; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
  • Otsuki S; QOL Research Laboratory, Gunze Limited, 1 Zeze Aonotyo Ayabe, Kyoto 623-8511, Japan.
  • Ikeda K; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
  • Okuno N; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
  • Okamoto Y; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
  • Wakama H; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
  • Okayoshi T; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
  • Neo M; Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigakumachi Takatsuki, Osaka 569-8686, Japan.
Appl Bionics Biomech ; 2021: 4931092, 2021.
Article en En | MEDLINE | ID: mdl-34777573
ABSTRACT
The assessment of the distribution of contact pressure on the meniscus is important in the elucidation of kinematics, etiology of joint diseases, and establishment of treatment methods. Compared with sensors widely used in recent years, pressure-sensitive conductive rubber sensors are easy to mold, flexible, durable, and resistant to shearing forces. This study is aimed at developing a rubber sensor for meniscal research and evaluating the pressure distribution after meniscal injury using porcine models. After confirming the reliability of the rubber sensor, contact pressure was obtained from the rubber sensor using the medial meniscus and femur of the porcine knee. Three test conditions of intact meniscus, radial tear, and meniscectomy were prepared, and a compressive load of 100 N was applied. After confirming the high reliability of the rubber sensor, the intact meniscus had the most uniform pressure distribution map, while the pressure in the meniscectomy model was concentrated in the resection region. The high-pressure region was significantly smaller in the intact group than in the radial tear models after 80 and 100 N (P < 0.05). The rubber sensor captured the pressure concentration specific to each examination group and was useful for evaluating the relationship between the pattern of meniscal injury and changes in the biomechanical condition of the knee.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Appl Bionics Biomech Año: 2021 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Appl Bionics Biomech Año: 2021 Tipo del documento: Article País de afiliación: Japón
...