Your browser doesn't support javascript.
loading
Balloon-Assisted Roadmap Technique to Enable Flow Diversion of a High-Flow Direct Carotid-Cavernous Fistula.
Jareczek, Francis J; Padmanaban, Varun; Church, Ephraim W; Simon, Scott D; Cockroft, Kevin M; Wilkinson, D Andrew.
Afiliación
  • Jareczek FJ; Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA.
  • Padmanaban V; Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA.
  • Church EW; Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA.
  • Simon SD; Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA.
  • Cockroft KM; Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA.
  • Wilkinson DA; Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA. Electronic address: dwilkinson@pennstatehealth.psu.edu.
J Stroke Cerebrovasc Dis ; 31(1): 106180, 2022 Jan.
Article en En | MEDLINE | ID: mdl-34823090
BACKGROUND: The use of flow diverters as a first-line treatment for direct carotid cavernous fistula (CCF) is a relatively new approach in the neurointerventional field which allows obliteration of the fistula with less mass effect from coils in the cavernous sinus. Safe and successful deployment of a flow diverter requires adequate imaging of the parent vessel, which may be challenging in the setting of high-flow CCF without antegrade flow. OBJECTIVE: To facilitate adequate parent vessel imaging in the setting of high-flow CCF to enable the safe development of a flow diverter device. METHODS: Here we present the case of a patient with delayed presentation of post-traumatic direct CCF after a motor vehicle accident, with no antegrade flow past the fistulous connection. We used temporary balloon occlusion of the fistulous connection to enable road-map imaging of the parent vessel and flow-diverter placement. "Drag and drop" device opening in the middle cerebral artery facilitated better deployment of the flow-diverter against retrograde cavernous flow through the fistula. RESULTS: Temporary balloon occlusion of the fistulous connection was used to acquire a roadmap to facilitate safe deployment of a flow diverter and subsequent treatment of the CCF with transvenous coil embolization, with complete resolution of symptoms. CONCLUSION: Balloon-assisted roadmap use is a novel means of visualizing the parent vessel in direct CCF to facilitate safe flow diverter deployment.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fístula del Seno Cavernoso de la Carótida / Oclusión con Balón / Embolización Terapéutica Límite: Humans Idioma: En Revista: J Stroke Cerebrovasc Dis Asunto de la revista: ANGIOLOGIA / CEREBRO Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fístula del Seno Cavernoso de la Carótida / Oclusión con Balón / Embolización Terapéutica Límite: Humans Idioma: En Revista: J Stroke Cerebrovasc Dis Asunto de la revista: ANGIOLOGIA / CEREBRO Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos