Your browser doesn't support javascript.
loading
[Efficacy of the XEN gel stent on intraocular pressure lowering in glaucoma patients].
Yao, Y H; Ye, Q; Wang, X H; Lin, Y; Zhu, Y H.
Afiliación
  • Yao YH; The First Affiliated Hospital of Fujian Medical University, Fujian Institute of Ophthalmology, Fuzhou 350004, China.
  • Ye Q; The First Affiliated Hospital of Fujian Medical University, Fujian Institute of Ophthalmology, Fuzhou 350004, China.
  • Wang XH; The First Affiliated Hospital of Fujian Medical University, Fujian Institute of Ophthalmology, Fuzhou 350004, China.
  • Lin Y; The First Affiliated Hospital of Fujian Medical University, Fujian Institute of Ophthalmology, Fuzhou 350004, China.
  • Zhu YH; The First Affiliated Hospital of Fujian Medical University, Fujian Institute of Ophthalmology, Fuzhou 350004, China.
Zhonghua Yan Ke Za Zhi ; 57(9): 679-684, 2021 Sep 11.
Article en Zh | MEDLINE | ID: mdl-34865405
Objective: To evaluate the efficacy and safety of the XEN gel implant in the treatment of glaucoma. Methods: It was a retrospective case series study. Eight patients (8 eyes) in the First Affiliated Hospital of Fujian Medical University from January 2020 to September 2020 were included, including six males and two females, aged 29 to 74 years. The patients treated with the XEN gel implanting for glaucoma. After detailed ophthalmic examination, all the patients met the surgical indications for the XEN gel implanting. Preoperative and postoperative intraocular pressure (IOP), anterior segment and fundus examination results, medication, and surgical complications were evaluated. Results: There were seven patients with primary open-angle glaucoma and one patient with glaucomatocyclitic syndrome. Five patients had received anti-glaucoma surgeries, and the remaining three patients had not received surgical treatment. All XEN gel stents were implanted successfully. All patients were followed up for 4 to 12 months. The preoperative maximum IOP ranged from 11 to 44 mmHg (median, 28 mmHg, 1 mmHg=0.133 kPa), and the IOP was 10 to 18 mmHg (median, 13 mmHg) at the last follow-up. Two to 4 types of medication were used for glaucoma preoperatively (median, 3), while 0 to 2 types (median, 0) were used at the last follow-up. During the follow-up, 7 cases were completely successful and only one case failed. Intraoperative hemorrhage occurred in two patients, and after effective treatment, the IOP decreased to below 20 mmHg. One patient was found to have an increased IOP with the XEN luminal obstruction, and the XEN drainage tube was recanalized. The IOP was about 10 mmHg at the last follow-up, and no anti-glaucoma drugs were used, but the surgery was assessed as failure by standard. The remaining patients had no other serious complications. Conclusion: This preliminary study shows that the XEN gel drainage may be a safe and effective treatment for patients with glaucoma. (Chin J Ophthalmol, 2021, 57: 679-684).
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glaucoma / Glaucoma de Ángulo Abierto / Implantes de Drenaje de Glaucoma Tipo de estudio: Observational_studies Límite: Female / Humans / Male Idioma: Zh Revista: Zhonghua Yan Ke Za Zhi Año: 2021 Tipo del documento: Article País de afiliación: China Pais de publicación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glaucoma / Glaucoma de Ángulo Abierto / Implantes de Drenaje de Glaucoma Tipo de estudio: Observational_studies Límite: Female / Humans / Male Idioma: Zh Revista: Zhonghua Yan Ke Za Zhi Año: 2021 Tipo del documento: Article País de afiliación: China Pais de publicación: China