Non-invasive tools for detection of liver disease in children and adolescents with cystic fibrosis.
Transl Pediatr
; 10(11): 2952-2959, 2021 Nov.
Article
en En
| MEDLINE
| ID: mdl-34976761
BACKGROUND: Cystic fibrosis (CF) is a multi-organ genetic disease caused by mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene which encodes the CFTR protein. CF-associated liver disease (CFLD) is a common complication; diagnosis is based on clinical, laboratory findings and abdominal imaging. However, non-invasive diagnostic approaches are needed to early detect CFLD, its progression and severity. Recent studies demonstrate a possible role of point shear wave elastography (p-SWE) with liver stiffness measurement (LSM) as a tool for CFLD diagnosis also in children. This non-invasive technique measures liver stiffness to assess liver fibrosis and is suggested to be less operator-dependent compared to ultrasonography. Aim of our prospective observational study is to investigate the role of p-SWE with LSM for CFLD diagnosis in children and adolescents with CF and to compare this finding with aspartate aminotransferase to platelet ratio index (APRI), fibrosis index based on four factors (FIB-4) and gamma-glutamyl-transpeptidase to platelet ratio (GPR) indices. METHODS: Fifty-nine children with CF, who had routinely undergone abdominal imaging, were consecutively enrolled. Laboratory findings and clinical data were recorded, as abdominal ultrasound and shear wave elastography at baseline. The cases were divided into two groups based on collected data and classified as CFLD and CFnoLD (without liver disease) according to Debray criteria. APRI, FIB-4 and GPR fibrosis indices were also evaluated. RESULTS: Twenty-four/59 (40.7%) were defined as CFLD. LSM test is superior to the APRI (P<0.001), the FIB-4 test (P=0.001) and the GPR test for early detection of liver fibrosis. LSM had an area under receiver operating characteristic (ROC) curve =0.818 (95% CI: 0.702-0.934) compared with APRI (0.571, 95% CI: 0.421-0.722), FIB-4 (0.656, 95% CI: 0.511-0.801) and GPR (0.632, 95% CI: 0.485-0.779). At a cut-off of ≥6.2 LSM show a sensitivity of 75.0% and a specificity of 88.6%. CONCLUSIONS: LSM by transient p-SWE is a non-invasive, highly accessible, reliable, and reproducible test that can be used to assess early detection of liver fibrosis and its severity in children and adolescents with CF, limiting the use of liver biopsy. These preliminary observations point to the need of larger study population to confirm our data.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Screening_studies
Idioma:
En
Revista:
Transl Pediatr
Año:
2021
Tipo del documento:
Article
País de afiliación:
Italia
Pais de publicación:
China