Your browser doesn't support javascript.
loading
Outcomes of Prostate Artery Embolisation in Patients with Severe Symptoms of Benign Prostate Hyperplasia.
Abdul Rahim, Rohana; Eng Hong, Goh; Nik Ismail, Nik Azuan; Zakaria, Rozman.
Afiliación
  • Abdul Rahim R; Department of Radiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Cheras, Kuala Lumpur, Malaysia.
  • Eng Hong G; Department of Surgery, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Cheras, Kuala Lumpur, Malaysia.
  • Nik Ismail NA; Department of Radiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Cheras, Kuala Lumpur, Malaysia.
  • Zakaria R; Department of Radiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Cheras, Kuala Lumpur, Malaysia.
Malays J Med Sci ; 28(6): 55-63, 2021 Dec.
Article en En | MEDLINE | ID: mdl-35002490
BACKGROUND: Benign prostatic hyperplasia (BPH) is associated with severe lower urinary tract symptoms (LUTS). The severity of LUTS is assessed by the International Prostate Symptoms Score (IPSS). Prostate artery embolisation (PAE) is a newly available method for combating LUTS. This study aims to assess the outcomes of PAE in reducing LUTS and prostate volume in patients with BPH. METHODS: Patients diagnosed with BPH with severe LUTS who had undergone PAE were included. Their IPSS score was ≥ 20 despite medical therapy. PAE was performed via the unilateral femoral artery using various types of embolic material. Bilateral or unilateral embolisation of the prostate artery was considered a technical success. The severity of LUTS pre- and post-PAE were assessed using IPSS while prostate volume pre- and post-PAE were assessed by ultrasound and magnetic resonance imaging (MRI). RESULTS: Ninety percent of patients had technical success and one required transurethral resection of the prostate (TURP). The mean IPSS reduction at the final follow-up was 12.9 (P < 0.028). The mean reduction of prostate volume at the last follow-up by ultrasound was 114.99 mL (P < 0.028) and by MRI was 29.17 mL (P < 0.028). CONCLUSION: PAE is safe and effective in reducing severe LUTS and prostate gland volume in BPH patients.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Malays J Med Sci Año: 2021 Tipo del documento: Article País de afiliación: Malasia Pais de publicación: Malasia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Malays J Med Sci Año: 2021 Tipo del documento: Article País de afiliación: Malasia Pais de publicación: Malasia