Radiotherapy-induced toxicity in prostate cancer patients with hip prostheses.
Fischer, Andrea M; Hoskin, Peter J.
Afiliación
  • Fischer AM; Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, HA6 2RN, UK. andrea.fischer@nhs.net.
  • Hoskin PJ; Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, HA6 2RN, UK.
Radiat Oncol ; 17(1): 9, 2022 Jan 17.
Article en En | MEDLINE | ID: mdl-35039065
ABSTRACT

INTRODUCTION:

Acute and late toxicity was analysed for prostate cancer patients with bilateral hip prostheses, who received fixed field intensity modulated radiotherapy (IMRT). The aims were (1) to establish whether toxicity rates differed from those of a control group with normal hips, (2) to develop a volumetric modulated arc therapy (VMAT) approach for patients with prostheses and (3) to compare doses to bladder and rectum for the control group, prostheses group and VMAT replans for the prostheses group.

METHODS:

Genitourinary (GU) and gastrointestinal (GI) toxicity was scored using Common Terminology Criteria for Adverse Events version 5.0. The incidence of grade 2 or worse (G2+) toxicity was compared using Fisher's exact test. Dose volume histograms (DVHs) and mean doses to organs at risk (OARs) were compared using signed rank tests.

RESULTS:

There were 17 patients in the prostheses group and 50 in the control group. Acute and late GU toxicity was similar. G2+ late GI toxicity incidence was 31% for the prostheses group and 14% for the control group (p = 0.14). Significant differences (p < 0.05) were seen between the OAR DVHs of the prostheses group who had IMRT and the control group for a range of intermediate doses. The rectum mean dose was significantly different (p < 0.001), but no difference was seen for the bladder mean dose (p = 0.08).

CONCLUSIONS:

No significant differences were seen in GU and GI toxicity incidence between patients with bilateral hip prostheses and a control group. The DVHs for bladder and rectum were significantly higher for patients with prostheses planned with IMRT. Replanning using a VMAT technique significantly reduced doses to the OARs, whilst maintaining good planning target volume coverage.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Neoplasias de la Próstata / Traumatismos por Radiación / Radioterapia de Intensidad Modulada / Enfermedades Gastrointestinales / Enfermedades Urogenitales / Prótesis de Cadera Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: Radiat Oncol Asunto de la revista: NEOPLASIAS / RADIOTERAPIA Año: 2022 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Neoplasias de la Próstata / Traumatismos por Radiación / Radioterapia de Intensidad Modulada / Enfermedades Gastrointestinales / Enfermedades Urogenitales / Prótesis de Cadera Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: Radiat Oncol Asunto de la revista: NEOPLASIAS / RADIOTERAPIA Año: 2022 Tipo del documento: Article País de afiliación: Reino Unido