Your browser doesn't support javascript.
loading
[Rotational alignment of the tibial component in total knee arthroplasty:a narrative review].
Umiti, Tashi; Liu, A F; Ji, N N; Cao, D D; Zhang, Y.
Afiliación
  • Umiti T; First Teaching Hospital of Tianjin University of Traditional Chinese Medicine,National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion,Tianjin 300381,China.
  • Liu AF; First Teaching Hospital of Tianjin University of Traditional Chinese Medicine,National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion,Tianjin 300381,China.
  • Ji NN; First Teaching Hospital of Tianjin University of Traditional Chinese Medicine,National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion,Tianjin 300381,China.
  • Cao DD; First Teaching Hospital of Tianjin University of Traditional Chinese Medicine,National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion,Tianjin 300381,China.
  • Zhang Y; First Teaching Hospital of Tianjin University of Traditional Chinese Medicine,National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion,Tianjin 300381,China.
Zhonghua Wai Ke Za Zhi ; 60(3): 268-272, 2022 Mar 01.
Article en Zh | MEDLINE | ID: mdl-35078302
ABSTRACT
Component malrotation is one of the major causes of failure in total knee arthroplasty.Based on previous researches,Insall line has excessive external rotation tendency.Although Akagi line is the most recognized anatomical axis at present,it still has a certain tendency of internal rotation.The tibial posterior condylar axis is not suitable for symmetrical component and yet the Curve-on-Curve technique is not suitable for anatomic component.In addition,reference to any fixed anatomical markers cannot ensure the rotation consistency of tibiofemoral component in extension position.Although range of motion technique is beneficial to tibiofemoral rotation synchronization,its clinical effect seems to be unstable.Nevertheless,Patients can obtain good postoperative results with all major techniques.Before the recognized "gold standard" is defined,orthopedic surgeons can determine the rotation alignment of tibial component according to their most accustomed surgical method.With a deeper understanding of knee anatomy,biomechanics and kinematics,digital assistive technology may be expected to become a breakthrough in the tibial rotational alignment.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Prótesis de la Rodilla Límite: Humans Idioma: Zh Revista: Zhonghua Wai Ke Za Zhi Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Prótesis de la Rodilla Límite: Humans Idioma: Zh Revista: Zhonghua Wai Ke Za Zhi Año: 2022 Tipo del documento: Article País de afiliación: China
...