Your browser doesn't support javascript.
loading
Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation.
Kayhan, B; Coskunseven, E.
Afiliación
  • Kayhan B; Department of Refractive Surgery, Dunya Eye Etiler Hospital, Istanbul, Turkey; Department of Ophthalmology, Sultan II. Abdulhamid Han Training and Research Hospital, University of Health Sciences, Istanbul, Turkey. Electronic address: drbelmakayhan@gmail.com.
  • Coskunseven E; Department of Refractive Surgery, Dunya Eye Etiler Hospital, Istanbul, Turkey; Faculty of Health Sciences, Istanbul Rumeli University, Istanbul, Turkey. Electronic address: efekanc@gmail.com.
J Fr Ophtalmol ; 45(4): 377-383, 2022 Apr.
Article en En | MEDLINE | ID: mdl-35093264
ABSTRACT

OBJECTIVE:

To evaluate changes in biometric variables and intraocular lens (IOL) calculation results after posterior chamber phakic IOL (PCPIOL) implantation.

METHODS:

This retrospective, observational study included 65 eyes of 38 patients who underwent PCPIOL (EVO Visian ICL) implantation for correction of myopia. Prior to and a minimum of one year (mean 14.9 months) after EVO Visian ICL implantation, biometric variables and IOL calculation results were compared. Optical biometry, including anterior chamber depth, axial length, flat, steep, and mean keratometry values and IOL calculation results for the Holladay 2, Hoffer Q, Haigis, and SRK/T formulas were measured using the IOLMaster 700 SWEPT Source OCT biometer. MAIN

RESULTS:

The mean anterior chamber depth decreased from 3.70±0.22mm to 3.34±0.39mm, the mean axial length increased from 26.61±1.61mm to 26.71±1.66mm, and the mean flat keratometry changed from 42.82±1.86 D to 42.73±1.83 D. These changes were statistically significant. The mean IOL power calculation also revealed a statistically significant decrease with all four formulas (ranging from 0.19 D to 0.30 D) after PCPIOL implantation.

CONCLUSIONS:

Biometric variables and IOL calculation results showed statistically significant changes one year after EVO Visian ICL implantations. However, IOL power calculations yielded a decrease of less than 0.50 D, inducing much less refractive deviation in the spectacle plane; and the change was primarily related to an increase in AL measurements. IOL power calculations in eyes with EVO Visian ICL in situ provided satisfactory and reliable results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Facoemulsificación / Lentes Intraoculares Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Fr Ophtalmol Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Facoemulsificación / Lentes Intraoculares Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Fr Ophtalmol Año: 2022 Tipo del documento: Article