Your browser doesn't support javascript.
loading
A Preliminary Assessment of Size-Fractionated Microplastics in Indoor Aerosol-Kuwait's Baseline.
Uddin, Saif; Fowler, Scott W; Habibi, Nazima; Sajid, Sufiya; Dupont, Sam; Behbehani, Montaha.
Afiliación
  • Uddin S; Environment and Life Sciences Research Center, Kuwait Institute for Scientific Research, P.O. Box. 24885, Safat 13109, Kuwait.
  • Fowler SW; School of Marine and Atmospheric Sciences, Stony Brook University, Stony Brook, NY 11794-5000, USA.
  • Habibi N; Institute Bobby, 8 Allée des Orangers, 06320 Cap d'Ail, France.
  • Sajid S; Environment and Life Sciences Research Center, Kuwait Institute for Scientific Research, P.O. Box. 24885, Safat 13109, Kuwait.
  • Dupont S; Environment and Life Sciences Research Center, Kuwait Institute for Scientific Research, P.O. Box. 24885, Safat 13109, Kuwait.
  • Behbehani M; Department of Biological and Environmental Sciences, University of Gothenburg, 405 30 Gothenburg, Sweden.
Toxics ; 10(2)2022 Feb 04.
Article en En | MEDLINE | ID: mdl-35202257
ABSTRACT
The omnipresence of microplastic (MP) in various environmental samples, including aerosols, has raised public health concerns; however, there is presently very limited information on MPs in indoor aerosol. This paper presents a unique dataset where smaller MPs have been sampled using a six-stage cascade impactor from indoor environments in Kuwait. The MP concentration in the indoor air varied between 3.2 and 27.1 particles m-3, and the relative MP concentration decreased linearly from the lowest to the highest size fraction. A significant effect of location was observed for the total number of MPs (F2,14 = 5.80, p = 0.02) and the inhalable fraction (F2,14 = 8.38, p = 0.005), while location had no effect on the respirable fraction (F2,14 = 0.54, p = 0.60). A significant effect of the type of air conditioning used was also observed for the total number of MPs (F2,19 = 5.58, p = 0.01) and the inhalable fraction (F2,19 = 6.45, p = 0.008), while location had no effect on the respirable fraction (F2,19 = 1.30, p = 0.30). For the total number of MPs and the inhalable fraction, the concentration was significantly higher for the split unit air-conditioning as compared to the central air-conditioning plants. The presence/absence of carpets had no significant effect on the MP concentrations (total F1,19 = 4.08, p = 0.06; inhalable F1,19 = 3.03, p = 0.10; respirable F1,19 = 4.27, p = 0.05). The shape was dominantly fibers, with few fragments in lower size fractions. These datasets represent the first baseline information for Kuwait, and the smaller MPs in all the samples further underscore the need to develop standardized protocols of MP collection in the ≤2.5 µm fraction that can have more conspicuous health implications.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Toxics Año: 2022 Tipo del documento: Article País de afiliación: Kuwait

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Toxics Año: 2022 Tipo del documento: Article País de afiliación: Kuwait