OBJECTIVES: This study sought to investigate the temporal association between changes in physiologic heart failure (HF) sensors, atrial fibrillation (AF) progression, and clinical HF in patients with cardiac resynchronization therapy implantable defibrillators (CRT-D) designed to monitor AF and HF daily. BACKGROUND: AF is a common comorbidity in HF; however, it is unclear if HF triggers AF, or vice-versa. Current implantable cardiac devices have sensors capable of quantifying HF status, which permits a greater understanding of the impact of AF on HF status and may help guide treatment. METHODS: The MultiSENSE (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients) study collected multiple sensor data indicative of HF status in patients with CRT-D followed for up to 12 months. Patients were grouped according to their longest daily AF burden: 1) at least 24 hours of AF (HIGH AF); 2) between 6 minutes and 24 hours (MID AF); and 3) <6 minutes (NO AF). Sensor data were aligned to the first qualifying AF event or a randomly selected day for patients in the NO AF group. RESULTS: Among 869 patients with daily AF data available, 98 patients had HIGH AF, 141 patients MID AF, and 630 patients NO AF. At baseline, history of AF, N-terminal pro hormone B-type natriuretic peptide and device-measured S3 were associated with development of AF. HeartLogic index increased before AF onset (Δ HeartLogic = 9.83 ± 2.49; P < 0.001). Multivariable time-dependent Cox regression showed an increased risk for HF events following a 24-hour AF episode compared with no 24-hour AF (hazard ratio: 1.96; 95% confidence interval: 1.03-3.74). CONCLUSIONS: Device-measured HF indicators worsened before AF onset, whereas clinical HF deterioration only became apparent after AF occurred. Thus, the sensitivity of methods to ascertain AF and HF status appear to influence the direction of perceived causality. (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients [MultiSENSE]; NCT01128166).
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Fibrilación Atrial
/
Desfibriladores Implantables
/
Insuficiencia Cardíaca
Tipo de estudio:
Etiology_studies
/
Risk_factors_studies
Límite:
Humans
Idioma:
En
Revista:
JACC Clin Electrophysiol
Año:
2022
Tipo del documento:
Article
Pais de publicación:
Estados Unidos