Your browser doesn't support javascript.
loading
Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing.
Sui, He; Li, Jin; Liu, Lin; Lv, Zhongwen; Zhang, Yunfei; Dai, Yongming; Mo, Zhanhao.
Afiliación
  • Sui H; China-Japan Union Hospital of Jilin University, Changchun, People's Republic of China.
  • Li J; Jilin Province People's Hospital, Changchun, People's Republic of China.
  • Liu L; The Department of Trauma Surgery, Shanghai Oriental Hospital, Shanghai, People's Republic of China.
  • Lv Z; China-Japan Union Hospital of Jilin University, Changchun, People's Republic of China.
  • Zhang Y; China-Japan Union Hospital of Jilin University, Changchun, People's Republic of China.
  • Dai Y; Central Research Institute, United Imaging Healthcare, Shanghai, 201800, People's Republic of China.
  • Mo Z; Central Research Institute, United Imaging Healthcare, Shanghai, 201800, People's Republic of China.
J Pain Res ; 15: 577-590, 2022.
Article en En | MEDLINE | ID: mdl-35241934
ABSTRACT

PURPOSE:

The three-dimensional (3D) sequence of magnetic resonance imaging (MRI) plays a critical role in the imaging of musculoskeletal joints; however, its long acquisition time limits its clinical application. In such conditions, compressed sensing (CS) is introduced to accelerate MRI in clinical practice. We aimed to investigate the feasibility of an isotropic 3D variable-flip-angle fast spin echo (FSE) sequence with CS technique (CS-MATRIX) compared to conventional 2D sequences in knee imaging.

METHODS:

Images from different sequences of both the accelerated CS-MATRIX and the corresponding conventional acquisitions were prospectively analyzed and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the structures within the knees were measured for quantitative analysis. The subjective image quality and diagnostic agreement were compared between CS-MATRIX and conventional 2D sequences. Quantitative and subjective image quality scores were statistically analyzed with the paired t-test and Wilcoxon signed-rank test, respectively. Diagnostic agreements of knee substructure were assessed using Cohen's weighted kappa statistic.

RESULTS:

For quantitative analysis, images from the CS-MATRIX sequence showed a significantly higher SNR than T2-fs 2D sequences for visualizing cartilage, menisci, and ligaments, as well as a higher SNR than proton density (pd) 2D sequences for visualizing menisci and ligaments. There was no significant difference between CS-MATRIX and 2D T2-fs sequences in subjective image quality assessment. The diagnostic agreement was rated as moderate to very good between CS-MATRIX and 2D sequences.

CONCLUSION:

This study demonstrates the feasibility and clinical potential of the CS-MATRIX sequence technique for detecting knee lesions The CS-MATRIX sequence allows for faster knee imaging than conventional 2D sequences, yielding similar image quality to 2D sequences.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Pain Res Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Pain Res Año: 2022 Tipo del documento: Article