Your browser doesn't support javascript.
loading
Vitamin K (phylloquinone and menaquinones) in foods - Cost-effective quantification by LC-ESI-MS/MS.
Jensen, Marie Bagge; Rød, Kari Elin; Svarc, Petra Loznjak; Oveland, Eystein; Jakobsen, Jette.
Afiliación
  • Jensen MB; Research Group for Bioactives, Analysis and Application, National Food Institute, Technical University of Denmark, Kemitorvet, 2800 Kgs. Lyngby, Denmark. Electronic address: Mabaj@FOOD.DTU.dk.
  • Rød KE; Seafood, Nutrition and Environmental State Dept., Institute of Marine Research, P.O. Box 1870 Nordnes, Bergen, Norway. Electronic address: KariElin.Rod@hi.no.
  • Svarc PL; Research Group for Bioactives, Analysis and Application, National Food Institute, Technical University of Denmark, Kemitorvet, 2800 Kgs. Lyngby, Denmark. Electronic address: Petlon@food.dtu.dk.
  • Oveland E; Seafood, Nutrition and Environmental State Dept., Institute of Marine Research, P.O. Box 1870 Nordnes, Bergen, Norway. Electronic address: Eov@hi.no.
  • Jakobsen J; Research Group for Bioactives, Analysis and Application, National Food Institute, Technical University of Denmark, Kemitorvet, 2800 Kgs. Lyngby, Denmark. Electronic address: jeja@food.dtu.dk.
Food Chem ; 385: 132672, 2022 Aug 15.
Article en En | MEDLINE | ID: mdl-35287105
ABSTRACT
Further research on vitamin K is necessary as growing evidence of vitamin K's importance in human health beyond blood coagulation and bone health is emerging. We present a cost-effective LC-ESI-MS/MS method for quantification of phylloquinone (PK), and menaquinones (MK) 4-10 in food using deuterium labelled (d7) compounds (d7-PK, d7-MK-4, d7-MK-7 and d7-MK-9) as internal standards. The validation of the method included assessment of matrix effect, limit of quantification (LOQ), precision, and trueness. The LC-ESI-MS/MS method runtime is 9 min. The method was compared to a validated LC-FLD method (CEN 14148), for quantification of vitamin K in broccoli, cheese, natto, liver, and microalgae. LOQs of the LC-ESI-MS/MS method were ≤4 µg/100 g food. The intra- and inter-assay precision was <15% for PK, MK-4, MK-7 and MK-9; <20% for MK-5, MK-8, and MK-10, and ≤25% for MK-6. No significant differences between the quantified content by the LC-ESI-MS/MS and LC-FLD methods were observed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vitamina K 1 / Vitamina K Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: Food Chem Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vitamina K 1 / Vitamina K Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: Food Chem Año: 2022 Tipo del documento: Article