Your browser doesn't support javascript.
loading
Contrast-Enhanced Ultrasound Reveals Partial Perfusion Recovery After Hindlimb Ischemia as Opposed to Full Recovery by Laser Doppler Perfusion Imaging.
Becker, Alyssa B; Chen, Lanlin; Ning, Bo; Hu, Song; Hossack, John A; Klibanov, Alexander L; Annex, Brian H; French, Brent A.
Afiliación
  • Becker AB; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
  • Chen L; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
  • Ning B; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
  • Hu S; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
  • Hossack JA; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
  • Klibanov AL; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA; Department of Medicine, Cardiovascular Division, University of Virginia, Charlottesville, Virginia, USA.
  • Annex BH; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA; Department of Medicine, Cardiovascular Division, University of Virginia, Charlottesville, Virginia, USA.
  • French BA; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA; Department of Medicine, Cardiovascular Division, University of Virginia, Charlottesville, Virginia, USA. Electronic address: bf4g@virginia.edu.
Ultrasound Med Biol ; 48(6): 1058-1069, 2022 06.
Article en En | MEDLINE | ID: mdl-35287996
Mouse models are critical in developing new therapeutic approaches to treat peripheral arterial disease (PAD). Despite decades of research and numerous clinical trials, the efficacy of available therapies is limited. This may suggest shortcomings in our current animal models and/or methods of assessment. We evaluated perfusion measurement methods in a mouse model of PAD by comparing laser Doppler perfusion imaging (LDPI, the most common technique), contrast-enhanced ultrasound (CEUS, an emerging technique) and fluorescent microspheres (conventional standard). Mice undergoing a femoral artery ligation were assessed by LDPI and CEUS at baseline and 1, 4, 7, 14, 28, 60, 90 and 150 d post-surgery to evaluate perfusion recovery in the ischemic hindlimb. Fourteen days after surgery, additional mice were measured with fluorescent microspheres, LDPI, and CEUS. LDPI and CEUS resulted in broadly similar trends of perfusion recovery until 7 d post-surgery. However, by day 14, LDPI indicated full recovery of perfusion, whereas CEUS indicated ∼50% recovery, which failed to improve even after 5 mo. In agreement with the CEUS results, fluorescent microspheres at day 14 post-surgery confirmed that perfusion recovery was incomplete. Histopathology and photoacoustic microscopy provided further evidence of sustained vascular abnormalities.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteriopatías Oclusivas / Enfermedad Arterial Periférica Límite: Animals Idioma: En Revista: Ultrasound Med Biol Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteriopatías Oclusivas / Enfermedad Arterial Periférica Límite: Animals Idioma: En Revista: Ultrasound Med Biol Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido