Your browser doesn't support javascript.
loading
Evaluation of Dynamic Contrast-Enhanced MRI Measures of Lung Congestion and Endothelial Permeability in Heart Failure: A Prospective Method Validation Study.
Cheriyan, Joseph; Roberts, Alexandra; Roberts, Caleb; Graves, Martin J; Patterson, Ilse; Slough, Rhys A; Schroyer, Rosemary; Fernando, Disala; Kumar, Subramanya; Lee, Sarah; Parker, Geoffrey J M; Sarov-Blat, Lea; McEniery, Carmel; Middlemiss, Jessica; Sprecher, Dennis; Janiczek, Robert L.
Afiliación
  • Cheriyan J; Research, GSK Clinical Unit Cambridge, Cambridge, UK.
  • Roberts A; Division of Experimental Medicine and Immunotherapeutics, University of Cambridge, Cambridge, UK.
  • Roberts C; Cardiovascular Clinical Trials Office, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Graves MJ; Clinical Imaging, GSK, Stevenage, UK.
  • Patterson I; Imaging Services, Bioxydyn Ltd, Manchester, UK.
  • Slough RA; Cardiovascular Clinical Trials Office, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Schroyer R; Department of Radiology, University of Cambridge, Cambridge, UK.
  • Fernando D; Cardiovascular Clinical Trials Office, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Kumar S; Cardiovascular Clinical Trials Office, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Lee S; Statistics, GSK, Collegeville, Pennsylvania, USA.
  • Parker GJM; Research, GSK Clinical Unit Cambridge, Cambridge, UK.
  • Sarov-Blat L; Research, GSK Clinical Unit Cambridge, Cambridge, UK.
  • McEniery C; Consulting, Amallis Consulting Ltd, London, UK.
  • Middlemiss J; Imaging Services, Bioxydyn Ltd, Manchester, UK.
  • Sprecher D; Centre for Medical Imaging Computing, Department of Computer Science, University College London, London, UK.
  • Janiczek RL; Research and Development, GSK, Crescent Drive, Philadelphia, Pennsylvania, USA.
J Magn Reson Imaging ; 56(2): 450-461, 2022 08.
Article en En | MEDLINE | ID: mdl-35343008
BACKGROUND: Methods for accurate quantification of lung fluid in heart failure (HF) are needed. Dynamic contrast-enhanced (DCE)-MRI may be an appropriate modality. PURPOSE: DCE-MRI evaluation of fraction of fluid volume in the interstitial lung space (ve ) and vascular permeability (Ktrans ). STUDY TYPE: Prospective, single-center method validation. POPULATION: Seventeen evaluable healthy volunteers (HVs), 12 participants with HF, and 3 with acute decompensated HF (ADHF). FIELD STRENGTH/SEQUENCE: T1 mapping (spoiled gradient echo variable flip angle acquisition) followed by dynamic series (three-dimensional spoiled gradient-recalled echo acquisitions [constant echo time, repetition time, and flip angle at 1.5 T]). ASSESSMENT: Three whole-chest scans were acquired: baseline (Session 1), 1-week later (Session 2), following exercise (Session 3). Extended Tofts model quantified ve and Ktrans (voxel-wise basis); total lung median measures were extracted and fitted via repeat measure analysis of variance (ANOVA) model. Patient tolerability of the scanning protocol was assessed. STATISTICAL TESTS: This was constructed as an experimental medicine study. PRIMARY ENDPOINTS: Ktrans and ve at baseline (HV vs. HF), change in Ktrans and ve following exercise, and following lung congestion resolution (ADHF). Ktrans and ve were fitted separately using ANOVA. Secondary endpoint: repeatability, that is, within-participant variability in ve and Ktrans between sessions (coefficient of variation estimated via mixed effects model). RESULTS: There was no significant difference in mean Ktrans between HF and HV (P ≤ 0.17): 0.2216 minutes-1 and 0.2353 minutes-1 (Session 1), 0.2044 minutes-1 and 0.2567 minutes-1 (Session 2), 0.1841 minutes-1 and 0.2108 minutes-1 (Session 3), respectively. ve was greater in the HF group (all scans, P ≤ 0.02). Results were repeatable between Sessions 1 and 2; mean values for HF and HV were 0.4946 and 0.3346 (Session 1), 0.4353 and 0.3205 (Session 2), respectively. There was minimal difference in Ktrans or ve between scans for participants with ADHF (small population precluded significance testing). Scanning was well tolerated. DATA CONCLUSION: While no differences were detected in Ktrans , ve was greater in chronic HF patients vs. HV, augmented beyond plasma and intracellular volume. DCE-MRI is a valuable diagnostic and physiologic tool to evaluate changes in fluid volume in the interstitial lung space associated with symptomatic HF. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Medios de Contraste / Insuficiencia Cardíaca Tipo de estudio: Guideline / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Medios de Contraste / Insuficiencia Cardíaca Tipo de estudio: Guideline / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos