Your browser doesn't support javascript.
loading
An Analysis of the Comparative Efficacy Between a Third-Generation and a Second-Generation Supraglottic Airway Device in Patients Undergoing Laparoscopic Cholecystectomy.
Hussain, Darvish; Kundal, Raksha; Kumar, Anil; Sabharwal, Nikki.
Afiliación
  • Hussain D; Anaesthesiology, Lady Hardinge Medical College, New Delhi, IND.
  • Kundal R; Anaesthesiology, Lady Hardinge Medical College, New Delhi, IND.
  • Kumar A; Anaesthesiology, Lady Hardinge Medical College, New Delhi, IND.
  • Sabharwal N; Anaesthesiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, IND.
Cureus ; 14(2): e22592, 2022 Feb.
Article en En | MEDLINE | ID: mdl-35355545
ABSTRACT
Background and objective Supraglottic airway devices are extensively used nowadays to secure the airway and minimize postoperative airway-related complications. This study aimed to evaluate whether the Baska® mask (BM) provides higher seal pressure and a better first-time insertion compared to the laryngeal mask airway (LMA) ProSeal™ (LMA-P) in adult laparoscopic cholecystectomy. Methodology This prospective, randomized, single-blinded interventional study was performed after obtaining ethical approval from the Institutional Ethics Committee at the Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi. Sixty adult patients of both genders scheduled for laparoscopic cholecystectomy under general anesthesia were divided into two groups, with 30 patients in each group. Our study observed the number of insertion attempts, time of insertion, oropharyngeal seal pressure (OSP), number of patients requiring manipulation for proper placement of supraglottic airway devices, and ease of insertion. Results There were no significant differences in terms of insertion attempts, ease of insertion, and laryngopharyngeal morbidity between the groups. The mean OSP at five minutes was 31.55 ±2.23 cm H2O, and that at 30 minutes was 35.86 ±3.70 cm H20 in the BM group, while in the LMA-P group, it was 24.17 ±3.74 cm H20 and 25.97 ±3.79 cm H20 respectively (p<0.001). In our study, the trend of OSP continued to increase in the BM group more than in the LMA-P group during surgery. Conclusion The BM provided better OSP than the LMA-P, which was observed throughout the surgery.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Aspecto: Ethics Idioma: En Revista: Cureus Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Aspecto: Ethics Idioma: En Revista: Cureus Año: 2022 Tipo del documento: Article