Predict alone, decide together: cardiac abnormality detection based on single lead classifier voting.
Aublin, Pierre G; Ben Ammar, Mouin; Fix, Jeremy; Barret, Michel; Behar, Joachim A; Oster, Julien.
Afiliación
  • Aublin PG; Université de Lorraine, INSERM U1254, IADI, Nancy, F-54000, France.
  • Ben Ammar M; ENSTA, Paris, France.
  • Fix J; LORIA, CNRS, CentraleSupélec, Université Paris-Saclay, F-57000 Metz, France.
  • Barret M; International Research Lab Georgia Tech-CNRS IRL 2958 CentraleSupélec, France.
  • Behar JA; AIMLab, Biomedical Engineering Faculty, Technion-IIT, Haifa, Israel.
  • Oster J; Université de Lorraine, INSERM U1254, IADI, Nancy, F-54000, France.
Physiol Meas ; 43(5)2022 05 25.
Article en En | MEDLINE | ID: mdl-35413703
ABSTRACT
Objective. A classifier based on weighted voting of multiple single-lead based models combining deep learning (DL) representation and hand-crafted features was developed to classify 26 cardiac abnormalities from different lead subsets of short-term electrocardiograms (ECG).Approach. A two-stage method was proposed for the multilead prediction. First a lead-agnostic hybrid classifier was trained to predict the pathologies from single-lead ECG signals. The classifier combined fully automated DL features extracted through a convolutional neural network with hand-crafted features through a fully connected layer. Second, a voting of the single-lead based predictions was performed. For the 12-lead subset, voting consisted in an optimised weighting of the output probabilities of all available single lead predictions. For other lead subsets, voting simply consisted in the average of the lead predictions.Main results. This approach achieved a challenge test score of 0.48, 0.47, 0.46, 0.46, 0.45 on the 12, 6, 4, 3, 2-lead subsets respectively on the 2021 Physionet/Computing in Cardiology challenge hidden test set. The use of an hybrid approach and more advanced voting layer improved some individual class classification but did not offer better generalization than our baseline fully DL approach.Significance. The proposed approach showed potential at correctly classifying main cardiac abnormalities and dealt well with reduced lead subsets.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cardiología / Electrocardiografía Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Physiol Meas Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cardiología / Electrocardiografía Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Physiol Meas Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Francia