Your browser doesn't support javascript.
loading
Three dimensional modeling of atrioventricular valves provides predictive guides for optimal choice of prosthesis.
Sazzad, Faizus; Goh, Jin Hao; Ong, Zhi Xian; Almsherqi, Zakaria Ali Moh; Lakshminarasappa, Satish R; Ramanathan, Kollengode R; Kofidis, Theo.
Afiliación
  • Sazzad F; Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore. faizus@u.nus.edu.
  • Goh JH; Department of Cardiac, Thoracic and Vascular Surgery, National University Heart Centre, Singapore, Singapore. faizus@u.nus.edu.
  • Ong ZX; Centre for Translational Medicine, National University of Singapore, MD6, 14 Medical Drive, Level-8 (South), Singapore, 117599, Singapore. faizus@u.nus.edu.
  • Almsherqi ZAM; Department of Biological Sciences, National University of Singapore, Singapore, Singapore.
  • Lakshminarasappa SR; Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
  • Ramanathan KR; Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
  • Kofidis T; Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
Sci Rep ; 12(1): 7432, 2022 05 06.
Article en En | MEDLINE | ID: mdl-35523789
Inaccuracies in intraoperative and preoperative measurements and estimations may lead to adverse outcomes such as patient-prosthesis mismatch. We aim to measure the relation between different dimensions of the atrioventricular valve complex in explanted porcine heart models. After a detailed physical morphology study, a cast of the explanted heart models was made using silicon-based materials. Digital models were obtained from three-dimensional scanning of the casts, showing the measured annulopapillary distance was 2.50 ± 0.18 cm, and 2.75 ± 0.36 cm for anterior and posterior papillary muscles of left ventricle, respectively. There was a significant linear association between the mitral annular circumference to anterior-posterior distance (p = 0.003, 95% CI 0.78-3.06), mitral annular circumference to interpapillary distance (p = 0.009, 95% CI 0.38-2.20), anterior-posterior distance to interpapillary distance (p = 0.02, 95% CI 0.10-0.78). Anterior-posterior distance appeared to be the most important predictor of mitral annular circumference compared to other measured distances. The mean length of the perpendicular distance of the tricuspid annulus, a, was 2.65 ± 0.54 cm; b was 1.77 ± 0.60 cm, and c was 3.06 ± 0.55 cm. Distance c was the most significant predictor for tricuspid annular circumference (p = 0.006, 95% CI 0.28-2.84). The anterior-posterior distance measured by three-dimensional scanning can safely be used to predict the annular circumference of the mitral valve. For the tricuspid valve, the strongest predictor for the circumference is the c-distance. Other measurements made from the positively correlated parameters may be extrapolated to their respective correlated parameters. They can aid surgeons in selecting the optimal prosthesis for the patients and improve procedural planning.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Insuficiencia de la Válvula Mitral Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Animals / Humans Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Insuficiencia de la Válvula Mitral Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Animals / Humans Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Reino Unido